A default Telegraf config file can be generated using the -sample-config flag:
telegraf -sample-config > telegraf.conf
To generate a file with specific inputs and outputs, you can use the
-input-filter and -output-filter flags:
telegraf -sample-config -input-filter cpu:mem:net:swap -output-filter influxdb:kafka
Global tags can be specific in the [global_tags]
section of the config file in
key="value" format. All metrics being gathered on this host will be tagged
with the tags specified here.
Telegraf has a few options you can configure under the agent
section of the
config.
- interval: Default data collection interval for all inputs
- round_interval: Rounds collection interval to 'interval' ie, if interval="10s" then always collect on :00, :10, :20, etc.
- metric_buffer_limit: Telegraf will cache metric_buffer_limit metrics for each output, and will flush this buffer on a successful write.
- collection_jitter: Collection jitter is used to jitter the collection by a random amount. Each plugin will sleep for a random time within jitter before collecting. This can be used to avoid many plugins querying things like sysfs at the same time, which can have a measurable effect on the system.
- flush_interval: Default data flushing interval for all outputs. You should not set this below interval. Maximum flush_interval will be flush_interval + flush_jitter
- flush_jitter: Jitter the flush interval by a random amount. This is primarily to avoid large write spikes for users running a large number of telegraf instances. ie, a jitter of 5s and flush_interval 10s means flushes will happen every 10-15s.
- debug: Run telegraf in debug mode.
- quiet: Run telegraf in quiet mode.
- hostname: Override default hostname, if empty use os.Hostname().
There are some configuration options that are configurable per input:
- name_override: Override the base name of the measurement. (Default is the name of the input).
- name_prefix: Specifies a prefix to attach to the measurement name.
- name_suffix: Specifies a suffix to attach to the measurement name.
- tags: A map of tags to apply to a specific input's measurements.
- interval: How often to gather this metric. Normal plugins use a single global interval, but if one particular input should be run less or more often, you can configure that here.
There are also filters that can be configured per input:
- namepass: An array of strings that is used to filter metrics generated by the current input. Each string in the array is tested as a glob match against measurement names and if it matches, the field is emitted.
- namedrop: The inverse of pass, if a measurement name matches, it is not emitted.
- fieldpass: An array of strings that is used to filter metrics generated by the current input. Each string in the array is tested as a glob match against field names and if it matches, the field is emitted.
- fielddrop: The inverse of pass, if a field name matches, it is not emitted.
- tagpass: tag names and arrays of strings that are used to filter measurements by the current input. Each string in the array is tested as a glob match against the tag name, and if it matches the measurement is emitted.
- tagdrop: The inverse of tagpass. If a tag matches, the measurement is not emitted. This is tested on measurements that have passed the tagpass test.
This is a full working config that will output CPU data to an InfluxDB instance
at 192.168.59.103:8086, tagging measurements with dc="denver-1". It will output
measurements at a 10s interval and will collect per-cpu data, dropping any
fields which begin with time_
.
[global_tags]
dc = "denver-1"
[agent]
interval = "10s"
# OUTPUTS
[[outputs.influxdb]]
url = "http://192.168.59.103:8086" # required.
database = "telegraf" # required.
precision = "s"
# INPUTS
[[inputs.cpu]]
percpu = true
totalcpu = false
# filter all fields beginning with 'time_'
drop = ["time_*"]
[[inputs.cpu]]
percpu = true
totalcpu = false
drop = ["cpu_time"]
# Don't collect CPU data for cpu6 & cpu7
[inputs.cpu.tagdrop]
cpu = [ "cpu6", "cpu7" ]
[[inputs.disk]]
[inputs.disk.tagpass]
# tagpass conditions are OR, not AND.
# If the (filesystem is ext4 or xfs) OR (the path is /opt or /home)
# then the metric passes
fstype = [ "ext4", "xfs" ]
# Globs can also be used on the tag values
path = [ "/opt", "/home*" ]
# Drop all metrics for guest & steal CPU usage
[[inputs.cpu]]
percpu = false
totalcpu = true
fielddrop = ["usage_guest", "usage_steal"]
# Only store inode related metrics for disks
[[inputs.disk]]
fieldpass = ["inodes*"]
# Drop all metrics about containers for kubelet
[[inputs.prometheus]]
urls = ["http://kube-node-1:4194/metrics"]
namedrop = ["container_"]
# Only store rest client related metrics for kubelet
[[inputs.prometheus]]
urls = ["http://kube-node-1:4194/metrics"]
namepass = ["rest_client_"]
This plugin will emit measurements with the name cpu_total
[[inputs.cpu]]
name_suffix = "_total"
percpu = false
totalcpu = true
This will emit measurements with the name foobar
[[inputs.cpu]]
name_override = "foobar"
percpu = false
totalcpu = true
This plugin will emit measurements with two additional tags: tag1=foo
and
tag2=bar
[[inputs.cpu]]
percpu = false
totalcpu = true
[inputs.cpu.tags]
tag1 = "foo"
tag2 = "bar"
Additional inputs (or outputs) of the same type can be specified,
just define more instances in the config file. It is highly recommended that
you utilize name_override
, name_prefix
, or name_suffix
config options
to avoid measurement collisions:
[[inputs.cpu]]
percpu = false
totalcpu = true
[[inputs.cpu]]
percpu = true
totalcpu = false
name_override = "percpu_usage"
drop = ["cpu_time*"]
Telegraf also supports specifying multiple output sinks to send data to,
configuring each output sink is different, but examples can be
found by running telegraf -sample-config
.
Outputs also support the same configurable options as inputs (pass, drop, tagpass, tagdrop)
[[outputs.influxdb]]
urls = [ "http://localhost:8086" ]
database = "telegraf"
precision = "s"
# Drop all measurements that start with "aerospike"
drop = ["aerospike*"]
[[outputs.influxdb]]
urls = [ "http://localhost:8086" ]
database = "telegraf-aerospike-data"
precision = "s"
# Only accept aerospike data:
pass = ["aerospike*"]
[[outputs.influxdb]]
urls = [ "http://localhost:8086" ]
database = "telegraf-cpu0-data"
precision = "s"
# Only store measurements where the tag "cpu" matches the value "cpu0"
[outputs.influxdb.tagpass]
cpu = ["cpu0"]