Notifications
You must be signed in to change notification settings - Fork 0
/
modbus.yaml
130 lines (109 loc) · 3.33 KB
/
modbus.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
esphome:
name: agm-bms-modbus
platform: ESP32
board: lolin32
wifi:
networks:
- ssid: "ssidname"
password: "passwordforwifi"
captive_portal:
ota:
platform: esphome
password: "optionalpassword"
logger:
web_server:
port: 80
uart:
id: uart4
tx_pin: GPIO17
rx_pin: GPIO16
baud_rate: 9600
stop_bits: 2
modbus:
id: modbus1
uart_id: uart4
modbus_controller:
- id: modbus_device
address: 0x01 # Address of the Modbus slave device on the bus
modbus_id: modbus1
setup_priority: -10
sensor:
- platform: modbus_controller
modbus_controller_id: modbus_device
id: pzem_high_voltage_alarm
name: "High Voltage Alarm Threshold"
address: 0x0000
unit_of_measurement: "V"
register_type: holding
value_type: U_WORD
filters:
- multiply: 0.01
- platform: modbus_controller
modbus_controller_id: modbus_device
id: pzem_low_voltage_alarm
name: "Low Voltage Alarm Threshold"
address: 0x0001
unit_of_measurement: "V"
register_type: holding
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: modbus_device
id: pzem_slave_address
name: "Slave Address"
address: 0x0002
unit_of_measurement: ""
register_type: holding
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: modbus_device
id: pzem_current_range
name: "Current Range"
address: 0x0003
unit_of_measurement: "A"
register_type: holding
value_type: U_WORD
filters:
- lambda: |-
if (x == 0) return 100;
else if (x == 1) return 50;
else if (x == 2) return 200;
else if (x == 3) return 300;
else return x;
- platform: modbus_controller
modbus_controller_id: modbus_device
name: "Current Range Setting"
address: 0x0003
register_type: holding
value_type: U_WORD
unit_of_measurement: "bit"
switch:
- platform: modbus_controller
modbus_controller_id: modbus_device
name: "Reset Energy"
address: 0x42
register_type: holding
write_lambda: |-
return 1;
button:
- platform: template
name: "Set Current Range to 300A"
on_press:
then:
- lambda: |-
std::vector<uint16_t> current_range_payload = {0x0003}; // 300A value change to your schunt
esphome::modbus_controller::ModbusController *controller = id(modbus_device);
esphome::modbus_controller::ModbusCommandItem set_current_range_command =
esphome::modbus_controller::ModbusCommandItem::create_write_single_command(controller, 0x0003, current_range_payload[0]);
controller->queue_command(set_current_range_command);
ESP_LOGI("ModbusLambda", "Set Current Range to 300A");
- platform: template
name: "Set ADRESS"
on_press:
then:
- lambda: |-
std::vector<uint16_t> current_range_payload = {0x01}; // adress change command
esphome::modbus_controller::ModbusController *controller = id(modbus_device);
esphome::modbus_controller::ModbusCommandItem set_current_range_command =
esphome::modbus_controller::ModbusCommandItem::create_write_single_command(controller, 0x0002, current_range_payload[0]);
controller->queue_command(set_current_range_command);
ESP_LOGI("ModbusLambda", "Set ADRESS");