Notifications
You must be signed in to change notification settings - Fork 0
/
Lab6b.sta.summary
185 lines (139 loc) · 4.4 KB
/
Lab6b.sta.summary
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
------------------------------------------------------------
Timing Analyzer Summary
------------------------------------------------------------
Type : Slow 1200mV 85C Model Setup 'MAX10_CLK1_50'
Slack : 6.614
TNS : 0.000
Type : Slow 1200mV 85C Model Setup 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 9.251
TNS : 0.000
Type : Slow 1200mV 85C Model Setup 'altera_reserved_tck'
Slack : 46.265
TNS : 0.000
Type : Slow 1200mV 85C Model Hold 'MAX10_CLK1_50'
Slack : 0.168
TNS : 0.000
Type : Slow 1200mV 85C Model Hold 'altera_reserved_tck'
Slack : 0.341
TNS : 0.000
Type : Slow 1200mV 85C Model Hold 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 0.342
TNS : 0.000
Type : Slow 1200mV 85C Model Recovery 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 13.536
TNS : 0.000
Type : Slow 1200mV 85C Model Recovery 'MAX10_CLK1_50'
Slack : 14.248
TNS : 0.000
Type : Slow 1200mV 85C Model Recovery 'altera_reserved_tck'
Slack : 47.765
TNS : 0.000
Type : Slow 1200mV 85C Model Removal 'altera_reserved_tck'
Slack : 0.885
TNS : 0.000
Type : Slow 1200mV 85C Model Removal 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 4.283
TNS : 0.000
Type : Slow 1200mV 85C Model Removal 'MAX10_CLK1_50'
Slack : 4.311
TNS : 0.000
Type : Slow 1200mV 85C Model Minimum Pulse Width 'MAX10_CLK1_50'
Slack : 9.502
TNS : 0.000
Type : Slow 1200mV 85C Model Minimum Pulse Width 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 9.708
TNS : 0.000
Type : Slow 1200mV 85C Model Minimum Pulse Width 'altera_reserved_tck'
Slack : 49.624
TNS : 0.000
Type : Slow 1200mV 0C Model Setup 'MAX10_CLK1_50'
Slack : 7.505
TNS : 0.000
Type : Slow 1200mV 0C Model Setup 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 9.970
TNS : 0.000
Type : Slow 1200mV 0C Model Setup 'altera_reserved_tck'
Slack : 46.618
TNS : 0.000
Type : Slow 1200mV 0C Model Hold 'MAX10_CLK1_50'
Slack : 0.173
TNS : 0.000
Type : Slow 1200mV 0C Model Hold 'altera_reserved_tck'
Slack : 0.305
TNS : 0.000
Type : Slow 1200mV 0C Model Hold 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 0.307
TNS : 0.000
Type : Slow 1200mV 0C Model Recovery 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 14.118
TNS : 0.000
Type : Slow 1200mV 0C Model Recovery 'MAX10_CLK1_50'
Slack : 14.724
TNS : 0.000
Type : Slow 1200mV 0C Model Recovery 'altera_reserved_tck'
Slack : 47.955
TNS : 0.000
Type : Slow 1200mV 0C Model Removal 'altera_reserved_tck'
Slack : 0.808
TNS : 0.000
Type : Slow 1200mV 0C Model Removal 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 3.838
TNS : 0.000
Type : Slow 1200mV 0C Model Removal 'MAX10_CLK1_50'
Slack : 3.880
TNS : 0.000
Type : Slow 1200mV 0C Model Minimum Pulse Width 'MAX10_CLK1_50'
Slack : 9.513
TNS : 0.000
Type : Slow 1200mV 0C Model Minimum Pulse Width 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 9.683
TNS : 0.000
Type : Slow 1200mV 0C Model Minimum Pulse Width 'altera_reserved_tck'
Slack : 49.647
TNS : 0.000
Type : Fast 1200mV 0C Model Setup 'MAX10_CLK1_50'
Slack : 13.936
TNS : 0.000
Type : Fast 1200mV 0C Model Setup 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 15.240
TNS : 0.000
Type : Fast 1200mV 0C Model Setup 'altera_reserved_tck'
Slack : 48.682
TNS : 0.000
Type : Fast 1200mV 0C Model Hold 'MAX10_CLK1_50'
Slack : 0.050
TNS : 0.000
Type : Fast 1200mV 0C Model Hold 'altera_reserved_tck'
Slack : 0.148
TNS : 0.000
Type : Fast 1200mV 0C Model Hold 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 0.150
TNS : 0.000
Type : Fast 1200mV 0C Model Recovery 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 16.902
TNS : 0.000
Type : Fast 1200mV 0C Model Recovery 'MAX10_CLK1_50'
Slack : 17.113
TNS : 0.000
Type : Fast 1200mV 0C Model Recovery 'altera_reserved_tck'
Slack : 49.207
TNS : 0.000
Type : Fast 1200mV 0C Model Removal 'altera_reserved_tck'
Slack : 0.399
TNS : 0.000
Type : Fast 1200mV 0C Model Removal 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 2.042
TNS : 0.000
Type : Fast 1200mV 0C Model Removal 'MAX10_CLK1_50'
Slack : 2.067
TNS : 0.000
Type : Fast 1200mV 0C Model Minimum Pulse Width 'MAX10_CLK1_50'
Slack : 9.141
TNS : 0.000
Type : Fast 1200mV 0C Model Minimum Pulse Width 'u0|sdram_pll|sd1|pll7|clk[0]'
Slack : 9.720
TNS : 0.000
Type : Fast 1200mV 0C Model Minimum Pulse Width 'altera_reserved_tck'
Slack : 49.419
TNS : 0.000
------------------------------------------------------------