Skip to content

mcci-catena/mcci-catena-provision

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

79 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

mcci-catena-provision

Set up an MCCI Catena via serial console (USB or regular)

This repository contains two programs.

mcci-catena-provision.bri (for Windows only at the moment) loads one or more network provisioning scripts into an MCCI Catena device built using the Catena-Arduino-Platform. It was primarily developed for configuring Catena boards for use with the The Things Network. However, the tool can be used for other purposes as desired.

provision-ttn.sh provides a streamlined registration flow when working with The Things Network. It registers the device with the network, then uses mcci-catena-provision to load the network-generated application credentials into the Catena.

Contents:

mcci-catena-provision.bri

Overview

mcci-catena-provision reads one or more scripts containing Catena-Arduino-Platform commands, sending each line sequentially to an Catena directly connected to the PC via USB, and checking the results. Simple variable substitution allows you to input provisioning information from the command line, if needed.

Several scripts (.cat files, where cat is short for "Catena") are provided with the package, to perform common tasks. These include:

  • catenainit-otaa.cat -- initialize a Catena for LoRa over-the-air authentication ("OTAA"), using information provided from the command line. See "Using catenainit-otaa.cat", below.

Usage

./bright mcci-catena-provision.bri -[options] [scripts ...]

The components of this command may be understood as follows.

bright mcci-catena-provision.bri invokes Terry Moore's Bright interpreter, which is included (in compiled form) in this package, to run mcci-catena-provision.bri. (Sources for Bright are available from Terry, contact author for information; posting to GitHub is pending.)

-[options] may be any of the following. Options are processed left to right. Unless we say otherwise, the rightmost option overrides any previous option setting. Boolean options may be negated using the "no" prefix; so for example write "-noD" to explicitly negate any previous -D option.

  • -baudrate # sets the desired baud rate. The default is 115200.
  • -D enables debug output to STDERR.
  • -echo causes script lines
  • -help outputs a brief reference, and exits.
  • -info outputs information about the Catena to STDOUT. This is intended to be used without any script files, in order to get information about the Catena being programmed.
  • -port portname selects the COM port to be used. Portname should usually be of the form com1, com2, etc. You can use Windows Device Manager > Ports (Com & LPT) to get a list of available ports.
  • -V name=value defines a variable named name, which can subsequently be used in script files (see "Script File Syntax", below). This option is cumulative. You may use it many times to define different variables.
  • -v selects verbose mode. Additional messages are logged to STDERR.
  • -write enables writing commands to the Catena. This is the default. -nowrite can be used on the command line to cause mcci-catena-provisions.bri to go through all the motions (macro expansion, etc.) but not download any data to the Catena. This is intended for use when debugging scripts.
  • -Werror says that any warning messages should be promoted to errors, resulting in error messages and non-zero exit status.

Catena Script File Syntax

Catena script files are processed line by line. Blank lines, and lines beginning with whitespace followed by # are treated as comments and ignored.

Otherwise the line is macro-expanded and then sent to the Catena.

Macros are indicated using the syntax ${NAME}, where NAME is either a special variable defined by mcci-catena-provision or else a variable defined using the -V option on the command line. An undefined variable will cause mcci-load-mode-profile to report an error.

The special variable SYSEUI is always set to the system EUI read from the Catena during initialization.

Scripting Reference

The scripting commands are defined by the Catena Arduino Platform -- see this command summary.

Using catenainit-otaa.cat

The OTAA script catenainit-otaa.cat expects that you will invoke mcci-catena-provision.bri with the following -V definitions:

  • -V APPEUI=0123456789abcdef -- this is 16-digit application EUI in hex, as displayed by ttnctl when you register your device. (Don't worry about byte reversal issues.)
  • -V APPKEY=0123456789abcdef0123456789abcdef -- this is the 32-digit application key assigned to your device by ttnctl when you register your device.

A simple workflow is:

  1. Connect your Catena to your PC with a USB cable.
  2. Get your device's EUI using mcci-catena-provision.bri and the -info option.
  3. Use that dev EUI to register your device using the TTN console, or the command line tool ttnctl (available here).
  4. Run mcci-catena-provision.bri again with the catenainit-otaa.cat script, specifying the AppEUI and the AppKey obtained in step 3.

This workflow is automated by provision-ttnsh, described below.

Here's an example of manual provisioning.

$ # get info about the Catena on port com11.
$ ./bright mcci-catena-provision.bri -port com11 -info
CatenaType: Catena 4630
Platform Version: 0.16.0.1
SysEUI: 0002CC0B001A2B50

$ # check ttnctl version
$ ttnctl version
  INFO Got build information                    Branch=master BuildDate=2019-05-21T08:12:24Z Commit=60b8cc50487095cce789df3c2dcc260e07307f10 Version=v2.10.2-dev
  INFO This is an up-to-date ttnctl build

$ # register the device with the network.
$ ttnctl devices register device-0002CC0B001A2B50 0002CC0B001A2B50
  INFO Using Application                        AppEUI=70B3D57ED000F563 AppID=test-do-not-use
  INFO Generating random AppKey...
  INFO Discovering Handler...                   Handler=ttn-handler-us-west
  INFO Connecting with Handler...               Handler=us-west.thethings.network:1904
  INFO Registered device                        AppEUI=70B3D57ED000F563 AppID=test-do-not-use AppKey=0123456789ABCDEF0123456789ABCDEF DevEUI=0002CC0B001A2B50 DevID=device-0002cc0b001a2b50

# # get the device information
$ ttnctl devices info device-0002cc0b001a2b50
  INFO Using Application                        AppEUI=70B3D57ED000F563 AppID=test-do-not-use
  INFO Discovering Handler...                   Handler=ttn-handler-us-west
  INFO Connecting with Handler...               Handler=us-west.thethings.network:1904
  INFO Found device

  Application ID: test-do-not-use
       Device ID: device-0002cc0b001a2b50
       Last Seen: never

    LoRaWAN Info:

     AppEUI: 70B3D57ED000F563
     DevEUI: 0002CC0B001A2B50
    DevAddr: <nil>
     AppKey: 0123456789ABCDEF0123456789ABCDEF
    AppSKey: <nil>
    NwkSKey: <nil>
     FCntUp: 0
   FCntDown: 0
    Options: FCntCheckEnabled, 32BitFCnt

$ # put the networking info into the device.
$ # ----> be sure to scroll right in the text box to get the entire command that follows:
$ ./bright mcci-catena-provision.bri -port com11 -echo -V APPEUI=0002CC0B001A2B50 -V APPKEY=0123456789ABCDEF0123456789ABCDEF catenainit-otaa.cat
lorawan configure deveui 0002CC0B001A2B50
lorawan configure appeui 70B3D57ED0000852
lorawan configure appkey 0123456789ABCDEF0123456789ABCDEF
lorawan configure fcntup 0
lorawan configure fcntdown 0
lorawan configure devaddr 0
lorawan configure join 1

$

provision-ttn.sh

This script uses ttnctl, the API tool for The Things Network, to automatically register a device.

Usage: provision-ttn.sh

provision-ttn.sh -[options] deveui

-[options] may be any of the following. Options are processed left to right. Unless we say otherwise, the rightmost option overrides any previous option setting. Boolean options may be negated using the "n" prefix; so for example write "-nD" to explicitly negate any previous -D option.

  • -a {appid} selects {appid} as the target application ID. If not specified, or if -a - is written, then the currently-selected ttnctl application is used.
  • -b {basename} sets the base name for the device. This is similar to the mass registration option in the TTN consol.
  • -D requests debug output.
  • -h {handler} specifies the TTN handler associated with this application. The default is ttn-handler-us-west.
  • -p {port} specifies the com port for the Catena. On Windows, this must include the com prefix.
  • -s {script} specifies the mcci-catena-provision script to be used for loading the information into the Catena.
  • -v requests verbose logging.

Environment Variables

TTNCTL, if set, gives the full pathname of the ttnctl executable image. If TTNCTL is not set, ttnctl must be available on the current PATH.

Example

$ ./provision-ttn.sh  -b iseechange- -a iseechange-01 -s catena-4618-otaa.cat -v -p com20 0002cc0100000346
CatenaType: Catena 4618
Platform Version: 0.16.0.1
SysEUI: 0002CC0100000346
  INFO Found one EUI "70B3D57ED0011966", selecting that one.
  INFO Updated configuration                    AppEUI=70B3D57ED0011966 AppID=iseechange-01
  INFO Using Application                        AppEUI=70B3D57ED0011966 AppID=iseechange-01
  INFO Generating random AppKey...
  INFO Discovering Handler...                   Handler=ttn-handler-us-west
  INFO Connecting with Handler...               Handler=us-west.thethings.network:1904
  INFO Registered device                        AppEUI=70B3D57ED0011966 AppID=iseechange-01 AppKey={redacted} DevEUI=0002CC0100000346 DevID
m=iseechange-0002cc0100000346
provision-from-ttnctl.sh: provisioning Catena
./mcci-catena-provision.bri:
  CatenaType: Catena 4618
  Platform Version: 0.16.0.1
  SysEUI: 0002CC0100000346
system configure syseui 0002CC0100000346
system configure platformguid b75ed77b-b06e-4b26-a968-9c15f222dfb2
lorawan configure deveui 0002CC0100000346
lorawan configure appeui 70B3D57ED0011966
lorawan configure appkey {redacted}
lorawan configure devaddr 0
lorawan configure fcntup 0
lorawan configure fcntdown 0
lorawan configure appskey 0
lorawan configure nwkskey 0
lorawan configure join 1
system configure operatingflags 1
./mcci-catena-provision.bri: No errors detected

mcci_catena_provision_actility.py

This script communicates with catena to get information for register it in Actility network via Thingpark Enterprise API, then it loads the catena script to device for complete the provisioning process.

Required

  • Python 3.5 or greater on windows, linux and mac (Installation steps here)
  • Install Python packages pyserial, requests and ruamel.yaml using following commands in terminal/command prompt:
    1. pip3 install pyserial
    2. pip3 install requests
    3. pip3 install ruamel.yaml
  • Actility user account
  • Catena Script File (It should be placed in the same repository as the script)

Notes

  1. You need to chose a directory for this script and supporting materials. If you use git clone, you'll specify the target directory; if you download the zip file from git, then you'll need to choose a place to unpack the files.

  2. Once the files are unpacked, please open the actility-config.yml file and edit client_id & client_credentials. For e.g. client_id : tpe-eu-api/xxxxx@yyy.com, client_credentials: <your_password>

Using mcci_catena_provision_actility.py

python mcci_catena_provision_actility.py -[options]

-[options] may be any of the following:

  • -D - enables debug output.
  • -port - selects the COM port to be used. For Example: -port COM11 (windows) or -port /dev/tty* (linux) or -port /dev/cu.* (Mac)
  • -baud - sets the desired baud rate. The default is 115200.
  • -info - outputs information about the Catena to STDOUT.
  • -v - selects verbose mode.
  • -V - name=value defines a variable named name, which can subsequently be used in ttnctl application configuration. This option is cumulative. You may use it many times to define different variables. For example, -V APPEUI=000A000100000047 -V APPKEY=0123456789ABCDEF0123456789ABCDEF -V BASENAME=mycatena4470- -V MODEL=LORA/GenericA.1revB_IN865_Rx2-SF12 -V APPID=mcci_chennai_mqtt_server
  • -echo - causes script lines.
  • -nowrite - disable writing commands from script file to the Catena.
  • -permissive - helps to set SYSEUI, if it isn't set
  • -r - register the device in actility network
  • -s - specifies the mcci-catena-provision script to be used for loading the information into the Catena.
  • -Werror - says that any warning messages should be promoted to errors, resulting in error messages and non-zero exit status.

Catena Script File

A number of provisioning scripts are provided for setting up Catenas; the files are named as {script}.cat. If your Catena has already been set up at the factory, you can use catena-otaa.cat. Here are the scripts by name and function:

  • catenainit-otaa.cat - Configure a Catena for OTAA
  • catena-4610-base-otaa.cat - Configure a Catena 4610 in production
  • catena-4612-otaa.cat - Configure a Catena 4612 in production
  • catena-4617-otaa.cat - Configure a Catena 4617 in production
  • catena-4618-otaa.cat - Configure a Catena 4618 in production
  • catena-4630-otaa.cat - Configure a Catena 4630 in production

The scripts conventionally get information from variables that are set up by you or by the script. The variables are:

  • BASENAME - The base name to be used for devices. This must be a legal DNS-like name (letters, digits and dashes). The device EUI is appended to the name. If you want a dash as a separator between the basename and the DEVEUI, you must end the basename value with a dash.
  • APPEUI - The Application EUI is a unique 64 bit identifier for the application on the network.
  • DEVEUI - The device EUI is a unique 64 bit identifier for the end-device on the network.
  • APPKEY - The App key is a unique 128 bit identifier which used to secure the communication between the device and the network. It is only known by the device and by the application.

Example (mcci_catena_provision_actility.py)

python mcci_catena_provision_actility.py -D -port COM25 -permissive -r -V BASENAME=catprov- -V APPEUI=70B3D53260000246 -V APPKEY=0123456789ABCDEF0123456789ABCDEF -V MODEL=LORA/GenericA.1revB_IN865_Rx2-SF12 -V APPID=mcci_chennai_mqtt_server -s catenainit-otaa.cat

Port COM25 opened
>>> system echo off

<<< system echo off
OK

CheckComms
>>> system version

<<< Board: Catena 4470
Platform-Version: 0.17.0.50
Arduino-LoRaWAN-Version: 0.6.0.20
Arduino-LMIC-Version: 3.0.99.5
MCCIADK-Version: 0.2.1
MCCI-Arduino-BSP-Version: 2.1.0
OK

>>> system configure syseui

<<< 00-02-cc-01-00-00-01-93
OK

Device Created:
{'ref': '1421589', 'name': 'catprov-0193', 'EUI': '0002CC0100000193', 'activationType': 'OTAA', 'deviceProfileId': 'LORA/GenericA.1revB_IN865_Rx2-SF12', 'connectivityPlanId': 'actility-tpe-cs/tpe-cp', 'processingStrategyId': 'ROUTE', 'routeRefs': ['40344'], 'applicationEUI': '70B3D53260000246'}

Device Info:
{'ref': '1421589', 'name': 'catprov-0193', 'EUI': '0002CC0100000193', 'activationType': 'OTAA', 'deviceClass': 'A', 'deviceProfileId': 'LORA/GenericA.1revB_IN865_Rx2-SF12', 'connectivityPlanId': 'actility-tpe-cs/tpe-cp', 'processingStrategyId': 'ROUTE', 'routeRefs': ['40344'], 'applicationEUI': '70B3D53260000246', 'commercialDetails': {'image': '/thingpark/wireless/rest/resources/files/logo/deviceProfile/7453', 'manufacturerName': 'Generic', 'manufacturerLogo': '/thingpark/wireless/rest/resources/files/logo/device/202'}}

DoScript: catenainit-otaa.cat
>>> lorawan configure deveui 0002CC0100000193

<<< OK

>>> lorawan configure appeui 70B3D53260000246

<<< OK

>>> lorawan configure appkey 0123456789ABCDEF0123456789ABCDEF

<<< OK

>>> lorawan configure fcntup 0

<<< OK

>>> lorawan configure fcntdown 0

<<< OK

>>> lorawan configure appskey 0

<<< OK

>>> lorawan configure nwkskey 0

<<< OK

>>> lorawan configure join 1

<<< OK

Port COM25 closed
No errors detected

mcci_catena_provision_chirpstack.py

This script communicates with Catena to get information for register it in chirpstack network via HTTP APIs, then it loads the Catena script to device for complete the provisioning process.

Required

  • Python 3.5 or greater on windows, linux and mac (Installation steps here)
  • Install Python package pyserial using following command in terminal/command prompt:
    1. pip3 install pyserial
    2. pip3 install PyNaCl
    3. pip3 install requests
  • Chirpstack backend user account
  • Catena script file (It should be placed in the same repository as the script)

Notes

  1. You need to chose a directory for this script and supporting materials. If you use git clone, you'll specify the target directory; if you download the zip file from git, then you'll need to choose a place to unpack the files.

  2. You need to create organization API key at console for provide it as authentication key when running the script.

Using mcci_catena_provision_chirpstack.py

python mcci_catena_provision_chirpstack.py -[options]

-[options] may be any of the following:

  • -D - enables debug output.
  • -port - selects the COM port to be used. For Example: -port COM11 (windows) or -port /dev/tty* (linux) or -port /dev/cu.* (Mac)
  • -baud - sets the desired baud rate. The default is 115200.
  • -info - outputs information about the Catena to STDOUT.
  • -v - selects verbose mode.
  • -V - name=value defines a variable named name, which can subsequently be used in ttnctl application configuration. This option is cumulative. You may use it many times to define different variables. For example, -V APPNAME=mycatena4450 -V BASENAME=device- -V DEVPROFILE=cdcprofile -V ORGNAME=chirpstack -V JOINEUI=0000000000000000
  • -echo - causes script lines.
  • -nowrite - disable writing commands from script file to the Catena.
  • -permissive - helps to set SYSEUI, if it isn't set
  • -r - register the device in ttn network
  • -s - specifies the mcci-catena-provision script to be used for loading the information into the Catena.
  • -Werror - says that any warning messages should be promoted to errors, resulting in error messages and non-zero exit status.

Catena Script File

A number of provisioning scripts are provided for setting up Catenas; the files are named as {script}.cat. If your Catena has already been set up at the factory, you can use catena-otaa.cat. Here are the scripts by name and function:

  • catenainit-otaa.cat - Configure a Catena for OTAA
  • catena-4610-base-otaa.cat - Configure a Catena 4610 in production
  • catena-4612-otaa.cat - Configure a Catena 4612 in production
  • catena-4617-otaa.cat - Configure a Catena 4617 in production
  • catena-4618-otaa.cat - Configure a Catena 4618 in production
  • catena-4630-otaa.cat - Configure a Catena 4630 in production

The scripts conventionally get information from variables that are set up by you or by the script. The variables are:

  • ORGNAME - The Chirpstack organization name.
  • APPNAME - The Chirpstack application name (the name, not the application key). The script uses this to register the device.
  • DEVPROFILE - The Chirpstack device profile name.
  • BASENAME - The base name to be used for devices. This must be a legal DNS-like name (letters, digits and dashes). The device EUI is appended to the name. If you want a dash as a separator between the basename and the DEVEUI, you must end the basename value with a dash.
  • JOINEUI - The Application EUI is a unique 64 bit identifier for the application on the network.
  • DEVEUI - The device EUI is a unique 64 bit identifier for the end-device on the network.

Example (mcci_catena_provision_chirpstack.py)

python mcci_catena_provision_chirpstack.py -D -port COM5 -r -V APPNAME=cdcapp -V BASENAME=device- -V DEVPROFILE=cdcprofile -V ORGNAME=ChirpStack -V JOINEUI=0000000000000000 -s catena-4470-otaa.cat
Port COM5 opened
>>> system echo off

<<< OK

CheckComms
>>> system version

<<< Board: Catena 4470
Platform-Version: 0.21.2
Arduino-LoRaWAN-Version: 0.9.1
Arduino-LMIC-Version: 4.0.1.1
MCCIADK-Version: 0.2.2
MCCI-Arduino-BSP-Version: 2.3.0
OK
EV_TXSTART

>>> system configure syseui

<<< 00-02-cc-01-00-00-01-93
OK

Registering device...

Device Created:
device-0002cc0100000193

Device Info:
{"device":{"devEUI":"0002cc0100000193","name":"device-0002cc0100000193","applicationID":"1","description":"","deviceProfileID":"redacted","skipFCntCheck":true,"referenceAltitude":0,"variables":{},"tags":{},"isDisabled":false},"lastSeenAt":null,"deviceStatusBattery":256,"deviceStatusMargin":256,"location":null}

DoScript: catena-4470-otaa.cat
>>> system configure syseui 0002CC0100000193

<<< OK

>>> system configure platformguid EA8568EC-5DAE-46EE-929A-A3F6B00A565E

<<< OK

>>> lorawan configure deveui 0002CC0100000193

<<< OK

>>> lorawan configure appeui 0000000000000000

<<< OK

>>> lorawan configure devaddr 0

<<< OK

>>> lorawan configure fcntup 0

<<< OK

>>> lorawan configure fcntdown 0

<<< OK

>>> lorawan configure join 1

<<< OK

>>> system configure operatingflags 1

<<< OK

Port COM5 closed
No errors detected

mcci_catena_provision_helium.py

This script communicates with catena to get information for register it in Helium network via Helium console cli, then it loads the catena script to device for complete the provisioning process.

Required

  • Python 3.5 or greater on windows, linux and mac (Installation steps here)
  • Install Python packages pyserial and pexpect using following commands in terminal/command prompt:
    1. pip3 install pyserial
    2. pip3 install pexpect
  • Helium console CLI. Download it here
  • Catena Script File (It should be placed in the same repository as the script)

Notes

  1. You need to chose a directory for this script and supporting materials. If you use git clone, you'll specify the target directory; if you download the zip file from git, then you'll need to choose a place to unpack the files.

  2. Once the files are unpacked, you'll also need to get some additional files, in particular helium-console-cli. You can put this on your executable path, but the easiest thing is to put it in the same directory as the script.

  3. The first time you use the CLI, you will need to provide an API key. To create an account key, go to your profile on Helium Console. From the top right corner, click: Account -> Profile. From there, you may generate a key with a specific name and role. The key will only display once. The first time you run the provisioning script, it will prompt you for this key. It will save the key in a local file: .helium-console-config.toml.

Using mcci_catena_provision_helium.py

python mcci_catena_provision_helium.py -[options]

-[options] may be any of the following:

  • -D - enables debug output.
  • -port - selects the COM port to be used. For Example: -port COM11 (windows) or -port /dev/tty* (linux) or -port /dev/cu.* (Mac)
  • -baud - sets the desired baud rate. The default is 115200.
  • -info - outputs information about the Catena to STDOUT.
  • -v - selects verbose mode.
  • -V - name=value defines a variable named name, which can subsequently be used in ttnctl application configuration. This option is cumulative. You may use it many times to define different variables. For example, -V APPEUI=000A000100000047 -V APPKEY=0123456789ABCDEF0123456789ABCDEF -V BASENAME=mycatena4470-
  • -echo - causes script lines.
  • -nowrite - disable writing commands from script file to the Catena.
  • -permissive - helps to set SYSEUI, if it isn't set
  • -r - register the device in helium network
  • -s - specifies the mcci-catena-provision script to be used for loading the information into the Catena.
  • -Werror - says that any warning messages should be promoted to errors, resulting in error messages and non-zero exit status.

Catena Script File

A number of provisioning scripts are provided for setting up Catenas; the files are named as {script}.cat. If your Catena has already been set up at the factory, you can use catena-otaa.cat. Here are the scripts by name and function:

  • catenainit-otaa.cat - Configure a Catena for OTAA
  • catena-4610-base-otaa.cat - Configure a Catena 4610 in production
  • catena-4612-otaa.cat - Configure a Catena 4612 in production
  • catena-4617-otaa.cat - Configure a Catena 4617 in production
  • catena-4618-otaa.cat - Configure a Catena 4618 in production
  • catena-4630-otaa.cat - Configure a Catena 4630 in production

The scripts conventionally get information from variables that are set up by you or by the script. The variables are:

  • BASENAME - The base name to be used for devices. This must be a legal DNS-like name (letters, digits and dashes). The device EUI is appended to the name. If you want a dash as a separator between the basename and the DEVEUI, you must end the basename value with a dash.
  • APPEUI - The Application EUI is a unique 64 bit identifier for the application on the network.
  • DEVEUI - The device EUI is a unique 64 bit identifier for the end-device on the network.
  • APPKEY - The App key is a unique 128 bit identifier which used to secure the communication between the device and the network. It is only known by the device and by the application.

Example (mcci_catena_provision_helium.py)

python mcci_catena_provision_helium.py -D -port COM25 -permissive -r -V APPEUI=000A000100000047 -V APPKEY=0123456789ABCDEF0123456789ABCDEF -V BASENAME=catena4470- -s catenainit-otaa.cat

Port COM25 opened
>>> system echo off

<<< system echo off
OK

CheckComms
>>> system version

<<< Board: Catena 4470
Platform-Version: 0.17.0.50
Arduino-LoRaWAN-Version: 0.6.0.20
Arduino-LMIC-Version: 3.0.99.5
MCCIADK-Version: 0.2.1
MCCI-Arduino-BSP-Version: 2.1.0
OK

>>> system configure syseui

<<< 00-02-cc-01-00-00-01-93
OK
using light sleep

HELIUM COMMAND: helium-console-cli device create 000A000100000047 0123456789ABCDEF0123456789ABCDEF 0002CC0100000193 catena4470-0002cc0100000193
HELIUM - Device Registered:
 Device {
    app_eui: "000A000100000047",
    app_key: "0123456789ABCDEF0123456789ABCDEF",
    dev_eui: "0002CC0100000193",
    id: "1d4b7fcd-3a61-40a3-93d0-7b50642648d9",
    name: "catena4470-0002cc0100000193",
    organization_id: "542a0c22-248c-423a-ad29-30a58e68543d",
    oui: 1,
}

HELIUM COMMAND: helium-console-cli device get 000A000100000047 0123456789ABCDEF0123456789ABCDEF 0002CC0100000193
HELIUM - Device Info:
 Device {
    app_eui: "000A000100000047",
    app_key: "0123456789ABCDEF0123456789ABCDEF",
    dev_eui: "0002CC0100000193",
    id: "1d4b7fcd-3a61-40a3-93d0-7b50642648d9",
    name: "catena4470-0002cc0100000193",
    organization_id: "542a0c22-248c-423a-ad29-30a58e68543d",
    oui: 1,
}

APPEUI: 000A000100000047
DEVEUI: 0002CC0100000193
APPKEY: 0123456789ABCDEF0123456789ABCDEF

Device Created Successfully
DoScript: catenainit-otaa.cat
>>> lorawan configure deveui 0002CC0100000193

<<< OK

>>> lorawan configure appeui 000A000100000047

<<< OK

>>> lorawan configure appkey 0123456789ABCDEF0123456789ABCDEF

<<< OK

>>> lorawan configure fcntup 0

<<< OK

>>> lorawan configure fcntdown 0

<<< OK

>>> lorawan configure appskey 0

<<< OK

>>> lorawan configure nwkskey 0

<<< OK

>>> lorawan configure join 1

<<< OK

Port COM25 closed
No errors detected

mcci_catena_provision_sigfox.py

This script communicates with catena to get information for register it in sigfox network via sigfox API, then it loads the catena script to device for complete the provisioning process.

Required

  • Python 3.5 or greater on windows, linux and mac (Installation steps here)
  • Install Python packages pyserial, pynacl and requests using following commands in terminal/command prompt:
    1. pip3 install pyserial
    2. pip3 install PyNaCl
    3. pip3 install requests
  • Sigfox backend user account

    The Sigfox backend provides a web application interface for device management and configuration of data integration, as well as standards based web APIs to automate the device management and implement the data integration. For login Sigfox backend, go to https://backend.sigfox.com/. To find the backend API credentials, follow the steps mentioned here. In case of queries about backend, please contact Sigfox support.

  • Catena script file (It should be placed in the same repository as the script)

    The tool depends on your device being able to get commands over a serial port. When you use the tool, you must give it a script that tells the tool how to communicate with the device. These scripts are traditionally called "Catena script files", and have the extension .cat. The tool uses the specified script to Sigfox credentials into the device over the device serial port. The script can also do application-specific setup (so you can combine steps during production); but that's not in scope for this discussion. If you're using MCCI Catena devices, start by using the catena-sigfox-base.cat script that accompanies this repository. If you've modified the command language, or are using a different device, you may need to modify the script. In that case, please use catena-sigfox-base.cat as a starting point.

Notes

You need to chose a directory for this script and supporting materials. If you use git clone, you'll specify the target directory; if you download the zip file from git, then you'll need to choose a place to unpack the files.

Using mcci_catena_provision_sigfox.py

python mcci_catena_provision_sigfox.py -[options]

-[options] may be any of the following:

  • -D - enables debug output.
  • -port - selects the COM port to be used. For Example: -port COM11 (windows) or -port /dev/tty* (linux) or -port /dev/cu.* (Mac)
  • -baud - sets the desired baud rate. The default is 115200.
  • -info - outputs information about the Catena to STDOUT.
  • -v - selects verbose mode.
  • -V - name=value defines a variable named name, which can subsequently be used in ttnctl application configuration. This option is cumulative. You may use it many times to define different variables. For example, -V DEVID=1415D16 -V KEY=0123456789ABCDEF0123456789ABCDEF -V BASENAME=device- -V PAC=0123456789ABCDEF01234567 -V DEVTYPEID=0123456789abcdef01234567
  • -echo - causes script lines.
  • -nowrite - disable writing commands from script file to the Catena.
  • -permissive - helps to set SYSEUI, if it isn't set
  • -r - register the device in actility network
  • -s - specifies the mcci-catena-provision script to be used for loading the information into the Catena.
  • -Werror - says that any warning messages should be promoted to errors, resulting in error messages and non-zero exit status.

Catena Script File

A number of provisioning scripts are provided for setting up Catenas; the files are named as {script}.cat. Here is the base script used for sigfox network:

  • catena-sigfox-base.cat - Configure a Catena

The scripts conventionally get information from variables that are set up by you or by the script. The variables are:

  • BASENAME - The base name to be used for devices. This must be a legal DNS-like name (letters, digits and dashes). The device ID is appended to the name. If you want a dash as a separator between the basename and the device ID, you must end the basename value with a dash.
  • DEVTYPEID - The device type id is a unique identifier for the application on the network.
  • PAC - The PAC is a unique value for proves the ownership of end-device on the network.
  • KEY - The key is a unique identifier which used to secure the communication between the device and the network. It is only known by the device and by the application.

Example (mcci_catena_provision_sigfox.py)

python mcci_catena_provision_sigfox.py -D -port COM32 -permissive -r -V BASENAME=device- -V DEVID=26240FE -V KEY=0123456789ABCDEF0123456789ABCDEF -V PAC=0123456789ABCDEF -V DEVTYPEID=501f6a9a4175811910adf528 -s catena-sigfox-base.cat

Port COM32 opened
>>> system echo off

<<< system echo off
OK

CheckComms
>>> system version

Command sent: system version

<<< Board: Catena 4612
Platform-Version: 0.19.0.30
Arduino-LoRaWAN-Version: 0.8.0
Arduino-LMIC-Version: 3.3.0
MCCIADK-Version: 0.2.2
MCCI-Arduino-BSP-Version: 2.8.0
OK

Board: Catena 4612
Platform-Version: 0.19.0.30
Arduino-LoRaWAN-Version: 0.8.0
Arduino-LMIC-Version: 3.3.0
MCCIADK-Version: 0.2.2
MCCI-Arduino-BSP-Version: 2.8.0


>>> system configure syseui

<<< 00-02-cc-01-00-00-06-22
OK

Enter API Login Id: **redacted**
Enter API Password:

Device Created:
{'id': '26240FE'}

Device Info:
{'id': '26240FE', 'name': 'device-26240FE', 'satelliteCapable': False, 'repeater
': False, 'messageModulo': 4096, 'state': 0, 'comState': 5, 'pac': '0123456789AB
CDEF', 'location': {'lat': 0.0, 'lng': 0.0}, 'deviceType': {'id': '501f6a9a41758
11910adf528'}, 'group': {'id': '4ab30f462564325177713118'}, 'lqi': 4, 'creationT
ime': 1617197032746, 'modemCertificate': {'id': '5fabcd5d80bd5658641e4415'}, 'pr
ototype': True, 'automaticRenewal': True, 'automaticRenewalStatus': 1, 'createdB
y': '5eb5a674e833d96c28dffafd', 'lastEditionTime': 1617197032503, 'lastEditedBy'
: '5eb5a674e833d96c28dffafd', 'activable': True}

DoScript: catena-sigfox-base.cat

>>> sigfox configure devid 26240FE

<<< OK

>>> sigfox configure pac 0123456789ABCDEF

<<< OK

>>> sigfox configure region 2

<<< OK

>>> sigfox configure encryption 0

<<< OK

Port COM32 closed
No errors detected

mcci_catena_provision_ttn.py

This script communicates with Catena to get information for register it in TTN network via ttn-lw-cli, then it loads the Catena script to device for complete the provisioning process.

Required

  • Python 3.5 or greater on windows, linux and mac (Installation steps here)
  • Install Python package pyserial using following command in terminal/command prompt:
    1. pip3 install pyserial
  • The Things Network CLI. Download it here
  • Catena script file (It should be placed in the same repository as the script)

Notes

  1. You need to chose a directory for this script and supporting materials. If you use git clone, you'll specify the target directory; if you download the zip file from git, then you'll need to choose a place to unpack the files.

  2. Set TTN cli path as environment variable TTNLWCLI.

  3. You'll need to generate configuration file for ttn-lw-cli from command terminal using the command ttn-lw-cli use [host]. Then, log in to the TTN console using ttn-lw-cli login.

Using mcci_catena_provision_ttn.py

python mcci_catena_provision_ttn.py -[options]

-[options] may be any of the following:

  • -D - enables debug output.
  • -port - selects the COM port to be used. For Example: -port COM11 (windows) or -port /dev/tty* (linux) or -port /dev/cu.* (Mac)
  • -baud - sets the desired baud rate. The default is 115200.
  • -info - outputs information about the Catena to STDOUT.
  • -v - selects verbose mode.
  • -V - name=value defines a variable named name, which can subsequently be used in ttnctl application configuration. This option is cumulative. You may use it many times to define different variables. For example, -V APPID=mycatena4450 -V BASENAME=device- -V JOINEUI=0000000000000000 -V FREQPLAN=US915 -V LORAVER=1.0.3
  • -echo - causes script lines.
  • -nowrite - disable writing commands from script file to the Catena.
  • -permissive - helps to set SYSEUI, if it isn't set
  • -r - register the device in ttn network
  • -s - specifies the mcci-catena-provision script to be used for loading the information into the Catena.
  • -Werror - says that any warning messages should be promoted to errors, resulting in error messages and non-zero exit status.

Catena Script File

A number of provisioning scripts are provided for setting up Catenas; the files are named as {script}.cat. If your Catena has already been set up at the factory, you can use catena-otaa.cat. Here are the scripts by name and function:

  • catenainit-otaa.cat - Configure a Catena for OTAA
  • catena-4610-base-otaa.cat - Configure a Catena 4610 in production
  • catena-4612-otaa.cat - Configure a Catena 4612 in production
  • catena-4617-otaa.cat - Configure a Catena 4617 in production
  • catena-4618-otaa.cat - Configure a Catena 4618 in production
  • catena-4630-otaa.cat - Configure a Catena 4630 in production

The scripts conventionally get information from variables that are set up by you or by the script. The variables are:

  • APPID - The TTN application ID (the name, not the application key). The script uses this to register the device and to obtain the keys.
  • BASENAME - The base name to be used for devices. This must be a legal DNS-like name (letters, digits and dashes). The device EUI is appended to the name. If you want a dash as a separator between the basename and the DEVEUI, you must end the basename value with a dash.
  • LORAVER - LoRaWAN version
  • FREQPLAN - Regional frequency (AU915, AS923, EU868, IN866, JP923, KR920, US915)
  • JOINEUI - The Application EUI is a unique 64 bit identifier for the application on the network.
  • DEVEUI - The device EUI is a unique 64 bit identifier for the end-device on the network.

Example (mcci_catena_provision_ttn.py)

python mcci_catena_provision_ttn.py -D -port COM25 -r -V APPID=ttn_test_app -V BASENAME=device- -V JOINEUI=0000
000000000000 -V FREQPLAN=US915 -V LORAVER=1.0.3 -s catena-4470-otaa.cat

Port COM25 opened
>>> system echo off

<<< system echo off
OK

CheckComms
>>> system version

Command sent: system version

<<< Board: Catena 4470
Platform-Version: 0.21.2
Arduino-LoRaWAN-Version: 0.9.1
Arduino-LMIC-Version: 4.0.1.1
MCCIADK-Version: 0.2.2
MCCI-Arduino-BSP-Version: 2.3.0
OK

>>> system configure syseui

<<< 00-02-cc-01-00-00-01-93
OK


 Catena Type: Catena 4470
 Platform Version: 0.21.2
 SysEUI: 0002cc0100000193

Creating TTN end device...
TTN COMMAND: ttn-lw-cli end-devices create ttn_test_app device-0002cc01
00000193 --join-eui 0000000000000000 --dev-eui 0002CC0100000193 --lorawan-versio
n 1.0.3 --lorawan-phy-version PHY_V1_0_3_REV_A --frequency-plan-id US_902_928_FS
B_2 --with-root-keys

{
  "ids": {
    "device_id": "device-0002cc0100000193",
    "application_ids": {
      "application_id": "ttn_test_app"
    },
    "dev_eui": "0002CC0100000193",
    "join_eui": "0000000000000000"
  },
  "created_at": "2021-09-06T13:08:01.417830782Z",
  "updated_at": "2021-09-08T07:16:24.666424283Z",
  "attributes": {
  },
  "network_server_address": "nam1.cloud.thethings.network",
  "application_server_address": "nam1.cloud.thethings.network",
  "join_server_address": "nam1.cloud.thethings.network",
  "lorawan_version": "MAC_V1_0_3",
  "lorawan_phy_version": "PHY_V1_0_3_REV_A",
  "frequency_plan_id": "US_902_928_FSB_2",
  "supports_join": true,
  "root_keys": {
    "root_key_id": "ttn-lw-cli-generated",
    "app_key": {
      "key": {redacted}
    },
    "nwk_key": {
      "key": {redacted}
    }
  }
}

Vars Dict:
 {'APPEUI': '0000000000000000', 'DEVEUI': '0002CC0100000193', 'APPKEY': 'redacted', 
 'APPID': 'ttn_test_app', 'BASENAME': 'device-', 'DEVID': 'device-0002cc0100000193', 
 'FREQPLAN': 'US915', 'FREQPLANID': 'US_902_928_FSB_2', 'LORAVER': '1.0.3', 
 'LORAPHYVER': 'PHY_V1_0_3_REV_A', 'SYSEUI': '0002CC0100000193', 'JOINEUI': '0000000000000000'}

DoScript: catena-4470-otaa.cat

>>> system configure syseui 0002CC0100000193

<<< OK

>>> system configure platformguid EA8568EC-5DAE-46EE-929A-A3F6B00A565E

<<< OK

>>> lorawan configure deveui 0002CC0100000193

<<< OK

>>> lorawan configure appeui 0000000000000000

<<< OK

>>> lorawan configure appkey {redacted}

<<< OK

>>> lorawan configure devaddr 0

<<< OK

>>> lorawan configure fcntup 0

<<< OK

>>> lorawan configure fcntdown 0

<<< OK

>>> lorawan configure appskey 0

<<< OK

>>> lorawan configure nwkskey 0

<<< OK

>>> lorawan configure join 1

<<< OK

>>> system configure operatingflags 1

<<< OK

Port COM25 closed
No errors detected

Credits

About

Set up an MCCI Catena device over USB

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages