Skip to content

Commit a76fc04

Browse files
committed
Add Indonesian HMI SCADA use case
1 parent e41cd15 commit a76fc04

1 file changed

Lines changed: 5 additions & 0 deletions

File tree

Lines changed: 5 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,5 @@
1+
<!doctype html>
2+
<html lang="id"><head><meta charset="utf-8" /><meta name="viewport" content="width=device-width, initial-scale=1" /><title>ARServer untuk Integrasi HMI dan SCADA</title><meta name="description" content="Gunakan ARServer untuk menjembatani nilai relay IEC 61850 MMS terpilih menjadi register Modbus TCP untuk HMI, SCADA, DCS, dan client engineering." /><meta name="robots" content="index, follow" /><link rel="canonical" href="https://masarray.github.io/arserver/id/penggunaan/hmi-scada/" /><link rel="alternate" hreflang="en" href="https://masarray.github.io/arserver/en/use-cases/hmi-scada/" /><link rel="alternate" hreflang="id" href="https://masarray.github.io/arserver/id/penggunaan/hmi-scada/" /><link rel="icon" type="image/png" href="/arserver/assets/arserver-icon.png" /><link rel="stylesheet" href="/arserver/styles.css" /><link rel="stylesheet" href="/arserver/polish.css" /><link rel="stylesheet" href="/arserver/language.css" /><link rel="stylesheet" href="/arserver/learn.css" /></head>
3+
<body class="learn-body"><header class="site-header"><a class="brand" href="/arserver/id/"><span class="brand-mark brand-mark--image"><img src="/arserver/assets/arserver-icon.png" alt="" /></span><span class="brand-copy"><strong>ARServer</strong><small>HMI/SCADA</small></span></a><nav class="nav-links"><a href="/arserver/id/">Produk</a><a href="/arserver/id/penggunaan/">Use Case</a><a href="/arserver/id/panduan/dari-nol-sampai-jalan/">Mulai</a></nav><div class="language-switcher"><a href="/arserver/en/use-cases/hmi-scada/">EN</a><a class="is-active" href="/arserver/id/penggunaan/hmi-scada/">ID</a></div></header>
4+
<main><section class="learn-hero page-shell"><div class="learn-hero__inner"><p class="eyebrow"><span></span> Use case HMI / SCADA</p><h1>Expose data relay IEC 61850 terpilih sebagai point Modbus TCP yang stabil.</h1><p>Use case ini cocok untuk tim yang HMI, SCADA, atau DCS-nya lebih mudah membaca Modbus TCP daripada IEC 61850 MMS langsung.</p></div></section>
5+
<section class="learn-layout page-shell"><aside class="learn-sidebar"><strong>Use case</strong><a href="/arserver/id/penggunaan/">Ringkasan</a><a class="is-active" href="/arserver/id/penggunaan/hmi-scada/">HMI/SCADA</a><a href="/arserver/id/penggunaan/fat-sat/">FAT/SAT</a><a href="/arserver/id/penggunaan/mqtt-dashboard/">MQTT Dashboard</a><a href="/arserver/id/belajar/iec-61850-ke-modbus/">IEC 61850 ke Modbus</a><a href="/arserver/wiki.html?doc=VALIDATION_MATRIX.md">Validation Matrix</a></aside><article class="learn-article"><div class="learn-article__header"><span>Route integrasi</span><h2>Relay / IED → ARServer → Modbus TCP → HMI/SCADA</h2></div><div class="learn-content"><p>ARServer membaca nilai IEC 61850 terpilih dari relay, menyimpannya di runtime cache, lalu expose point mapping melalui Modbus TCP server. HMI atau SCADA polling ARServer tanpa perlu berbicara IEC 61850 langsung.</p><h3>Signal awal yang paling masuk akal</h3><ul><li>Posisi breaker atau switch.</li><li>Start, trip, dan operation indication proteksi.</li><li>Alarm utama dan status equipment.</li><li>Measurement dengan scaling dan unit yang jelas.</li></ul><h3>Yang wajib didokumentasikan</h3><p>Setiap point Modbus perlu address, tipe data, scale, arti Boolean, source IEC object, quality behavior, stale behavior, dan interpretasi HMI yang diharapkan.</p><div class="learn-callout"><strong>Jangan handover hanya nomor register.</strong> Modbus map tanpa source object, quality handling, dan stale behavior bukan deliverable engineering yang aman.</div><h3>Checklist acceptance</h3><ol><li>Komunikasi IED stabil di jaringan test.</li><li>Object IEC terpilih terbaca benar.</li><li>Modbus client bisa polling semua point mapping.</li><li>HMI menampilkan arti dan scaling yang benar.</li><li>Communication loss menghasilkan stale atau diagnostic state yang terlihat.</li></ol><div class="learn-link-grid"><a href="/arserver/id/belajar/iec-61850-ke-modbus/"><strong>Pelajari konsep bridge</strong><span>Pahami bagaimana object IEC 61850 menjadi register Modbus.</span></a><a href="/arserver/id/panduan/dari-nol-sampai-jalan/"><strong>Buat route pertama</strong><span>Ikuti workflow dari nol sebelum menambah banyak point.</span></a></div></div></article></section></main></body></html>

0 commit comments

Comments
 (0)