Update LC-Technology-WiFi-Relay.md
Fix relay not switching because mode is wrong.
1 parent 36ce93c commit 24334f2

File tree

1 file changed

+6
-0
lines changed

1 file changed

+6
-0
lines changed

docs/devices/LC-Technology-WiFi-Relay.md

Lines changed: 6 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -66,6 +66,12 @@ Rule1
6666
```
6767
Enable the rule (type `rule1 1` in the Tasmota console)
6868

69+
If your relay is still not switching, check the LED on the board.
70+
If LED D5 is on (blue on my board, the middle LED) then the controller is in Mode 2.
71+
By pressing S2 while power up you can change back to Mode 1.
72+
After that the LED D7 is on ( red in my case) an the device works like a charm.