forked from wimb0/saj_modbus
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathmodbus.yaml
2125 lines (2059 loc) · 54.2 KB
/
modbus.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
#################################################################
## Modbus
#################################################################
# From https://community.home-assistant.io/t/saj-solar-inverter/111932
# Updated with regs from AS1Main control board doc.
# along with some findings with my SAJ H2 10K-T2
##########################################################
## SAJ converter
##########################################################
# 0x001D = 29 PV1Volt ?
# 0x3651 = 13905
# 0x4000 = 16384 - realtime
# 0xe468 = 58472
- name: SAJ
close_comm_on_error: true
delay: 5
type: tcp
timeout: 5
host: 192.168.0.32
port: 502
sensors:
# From AS1 doc - does not work on H2
# # 0x3371, 1=Automatic Scheduling mode, 2=Time Of Use mode, 3 = Backup mode
# - name: ACC_UserMode
# slave: 0
# address: 13169
# count: 1
# scale: 1
# precision: 0
# data_type: uint16
# scan_interval: 1
# # 0x3600, 1=Automatic Scheduling mode, 2=Time Of Use mode, 3 = Backup mode
# - name: GridChargeEnable
# slave: 0
# address: 13824
# count: 1
# scale: 1
# precision: 0
# data_type: uint16
# scan_interval: 1
# - name: GridDischargeEnable
# slave: 0
# address: 13825
# count: 1
# scale: 1
# precision: 0
# data_type: uint16
# scan_interval: 1
# -----------------------------
# 0x001D = 29 PV1Volt does not return anything
# - name: PV1Volt
# unit_of_measurement: "V"
# slave: 0
# address: 29
# count: 1
# scale: 1
# precision: 1
# data_type: uint16
# device_class: voltage
# scan_interval: 10
- name: InverterDate
unit_of_measurement: "0xYYYYMMDD"
slave: 0
address: 16384
count: 2
scale: 1
precision: 0
data_type: uint32
device_class: time
scan_interval: 10
- name: InverterTime
unit_of_measurement: "0xHHMMSSxx"
slave: 0
address: 16386
count: 2
scale: 1
precision: 0
data_type: uint32
device_class: time
scan_interval: 10
- name: Inverter_working_mode
slave: 0
address: 16388
count: 1
scale: 1
precision: 0
data_type: uint16
scan_interval: 1
- name: display_board_error_message
slave: 0
address: 16389
count: 2
scale: 1
precision: 0
data_type: uint32
scan_interval: 10
- name: display_controller_error_message
slave: 0
address: 16391
count: 2
scale: 1
precision: 0
data_type: uint32
scan_interval: 10
- name: display_controller_error_message2
slave: 0
address: 16393
count: 2
scale: 1
precision: 0
data_type: uint32
scan_interval: 10
- name: error_message_controller
slave: 0
address: 16395
count: 2
scale: 1
precision: 0
data_type: uint32
scan_interval: 10
- name: error_message_controller2
slave: 0
address: 16397
count: 2
scale: 1
precision: 0
data_type: uint32
scan_interval: 10
# 0x4031 = 16433
#4031H 1 RGridVolt Uint16 -1 V R R phase voltage
#4032H 1 RGridCurr Int16 -2 A R R phase current
#4033H 1 RGridFreq Uint16 -2 Hz R R phase frequency
#4034H 1 RGridDCI Int16 0 mA R R phase DC component of grid
#4035H 1 RGridPowerWatt Int16 0 W R R phase grid active power
#4036H 1 RGridPowerVA Uint16 0 W R Rphase grid reactive power
#4037H 1 RGridPowerPF Int16 -3 R R phase grid power factor
#4046H 1 RInvVolt Uint16 -1 V R R phase Inversion voltage
#4047H 1 RInvCurr Int16 -2 A R R phase Inversioncurrent
#4048H 1 RInvFreq Uint16 -2 Hz R R inv frequency
#4049H 1 RInvPowerWatt Int16 0 W R R inv active power
#404AH 1 RInvPowerVA Uint16 0 VA R R inv reactive power
#4055H 1 ROutVolt Uint16 -1 V R R export voltage
#4056H 1 ROutCurr Uint16 -2 A R R export current
#4057H 1 ROutFreq Uint16 -2 Hz R R export frequency
#4058H 1 ROutDVI Int16 0 mV R RDC component of output voltage
#4059H 1 ROutPowerWatt Uint16 0 W R R output active power
#405AH 1 ROutPowerVA Uint16 0 VA R R output apparent power
# as 4055-405A for phase2 and phase 3
#4067H 1 BusVoltMaster Uint16 -1 V R Mast BUS voltage
#4068H 1 BusVoltSlave Uint16 -1 V R Slave BUS voltage
#4069H 1 BatVolt Uint16 -1 V R Battery voltage
#406AH 1 BatCurr Int16 -2 A R Battery current
#406DH 1 BatPower Int16 0 W R Battery power
#406EH 1 BatTempC Int16 -1 ℃ R Battery temperature
#406FH 1 BatEnergyPercent Uint16 -2 % R Battery SOC
#4095H 1 PV_direction Uint16 0 R PV direction of energy flow
#4096H 1 Battery_direction int16 0 R battery energy flow direction
#4097H 1 Grid_direction int16 0 R Grid energy flow direction
#4098H 1 OutPut_direction Uint16 0 R Output to load energy flow direction
#4099H 1 PVConsumpWatt Int16 0 W R Power flow from PV to load
#409AH 1 GridConsumpWatt Int16 0 W R Power flowing from the grid to the load
#409BH 1 GridFeedInPVWatt Int16 0 W R Power flow from PV to grid
#409CH 1 GridFeedInBatWatt Int16 0 W R Power flow from battery to grid
#409DH 1 BatConsumpWatt Int16 0 W R Power flow from battery to load
#409EH 1 BatChgPVWatt Int16 0 W R PV charging power to battery
#409FH 1 BatChgGridWatt Int16 0 W R Grid charging power to battery
#40A0H 1 SysTotalLoadWatt Int16 0 W R Total system load power consumption
#40A1H 1 CT_GridPowerWatt int16 0 W R CT grid active power
#40A2H 1 CT_GridPowerVA int16 0 VA R CT grid apparent power
#40A3H 1 CT_PVPowerWatt int16 0 W R CT PV active power
#40A4H 1 CT_PVPowerVA int16 0 VA R CT PV apparent power
#40A5H 1 TotalPVPower Int16 0 W R PV total power
#40A6H 1 TotalBatteryPower Int16 0 W R Total battery power
#40A7H 1 TotalGridPowerWatt Int16 0 W R The total active power of the grid
#40A8H 1 TotalGridPowerVA Int16 0 VA R The total apparent power of the grid
#40A9H 1 TotalInvPowerWatt Int16 0 W R Inverter total active power
#40AAH 1 TotalInvPowerVA Int16 0 VA R Inverter total apparent power
#40ABH 1 BackupTotalLoadPowerWatt Uint16 0 W R Backup Total load active power
#40ACH 1 BackupTotalLoadPowerVA Uint16 0 VA R Backup Total load apparent power
#40ADH 1 BatChgPowerLimit Int16 0 W R PV Charging limit
- name: Grid_phase_voltage
unit_of_measurement: "V"
slave: 0
address: 16433
count: 1
scale: 1
precision: 1
data_type: uint16
device_class: voltage
scan_interval: 1
# Following 3 does not match Smart meter I
- name: Grid_Phase_current
unit_of_measurement: "A"
slave: 0
address: 16434
count: 1
precision: 2
scale: 0
data_type: int16
device_class: current
scan_interval: 1
- name: Grid_Frequency
unit_of_measurement: "Hz"
slave: 0
address: 16435
count: 1
precision: 2
scale: 0
data_type: int16
device_class: frequency
scan_interval: 1
- name: GridDCI
unit_of_measurement: "mA"
slave: 0
address: 16436
count: 1
precision: 2
scale: 0
data_type: int16
device_class: current
scan_interval: 1
- name: GridPowerWatt
unit_of_measurement: "W"
slave: 0
address: 16437
count: 1
precision: 0
scale: 0
data_type: int16
device_class: power
scan_interval: 1
- name: GridPowerVA
unit_of_measurement: "W"
slave: 0
address: 16438
count: 1
precision: 0
scale: 0
data_type: int16
device_class: current
scan_interval: 1
#0x4055
- name: Grid1OutVolt
unit_of_measurement: "V"
slave: 0
address: 16469
count: 1
precision: 1
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid1OutCurrent
unit_of_measurement: "A"
slave: 0
address: 16470
count: 1
precision: 2
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid1OutFrequency
unit_of_measurement: "Hz"
slave: 0
address: 16471
count: 1
precision: 2
scale: 1
data_type: uint16
device_class: frequency
scan_interval: 1
# RDC
- name: Grid1OutDVI
unit_of_measurement: "mV"
slave: 0
address: 16472
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid1OutPowerWatt
unit_of_measurement: "W"
slave: 0
address: 16473
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
- name: Grid1OutPowerVA
unit_of_measurement: "VA"
slave: 0
address: 16474
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
# 16475 0x405B- unknown, but appears to be as above but for the other phases
- name: Grid2OutVolt
unit_of_measurement: "V"
slave: 0
address: 16475
count: 1
precision: 1
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid2OutCurrent
unit_of_measurement: "A"
slave: 0
address: 16476
count: 1
precision: 2
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid2OutFrequency
unit_of_measurement: "Hz"
slave: 0
address: 16477
count: 1
precision: 2
scale: 1
data_type: uint16
device_class: frequency
scan_interval: 1
# RDC
- name: Grid2OutDVI
unit_of_measurement: "mV"
slave: 0
address: 16478
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid2OutPowerWatt
unit_of_measurement: "W"
slave: 0
address: 16479
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
- name: Grid2OutPowerVA
unit_of_measurement: "VA"
slave: 0
address: 16480
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
- name: Grid3OutVolt
unit_of_measurement: "V"
slave: 0
address: 16481
count: 1
precision: 1
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid3OutCurrent
unit_of_measurement: "A"
slave: 0
address: 16482
count: 1
precision: 2
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid3OutFrequency
unit_of_measurement: "Hz"
slave: 0
address: 16483
count: 1
precision: 2
scale: 1
data_type: uint16
device_class: frequency
scan_interval: 1
# RDC
- name: Grid3OutDVI
unit_of_measurement: "mV"
slave: 0
address: 16484
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Grid3OutPowerWatt
unit_of_measurement: "W"
slave: 0
address: 16485
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
- name: Grid3OutPowerVA
unit_of_measurement: "VA"
slave: 0
address: 16486
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
- name: Battery_voltage
unit_of_measurement: "V"
slave: 0
address: 16489
count: 1
precision: 1
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: Battery_current
unit_of_measurement: "A"
slave: 0
address: 16490
count: 1
precision: 2
scale: 1
data_type: int16
device_class: current
- name: Battery_power
unit_of_measurement: "W"
slave: 0
address: 16493
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: Battery_temperature
# Was wrong address
#"C°"
unit_of_measurement: "C"
slave: 0
address: 16494
count: 1
precision: 1
scale: 1
data_type: int16
scan_interval: 1
device_class: temperature
- name: Battery_SOC
unit_of_measurement: "%"
slave: 0
address: 16495
count: 1
precision: 0
scale: 0.01
data_type: uint16
device_class: battery
scan_interval: 1
# Empiric study suggests this could be PV values
# - name: PV1x
# unit_of_measurement: "V"
# slave: 0
# address: 16496
# count: 1
# precision: 1
# scale: 0
# data_type: uint16
# device_class: voltage
# scan_interval: 1
- name: PV1Volt
unit_of_measurement: "V"
slave: 0
address: 16497
count: 1
precision: 1
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: PV1Current
unit_of_measurement: "A"
slave: 0
address: 16498
count: 1
precision: 2
scale: 1
data_type: uint16
device_class: current
scan_interval: 1
- name: PV1Power
unit_of_measurement: "W"
slave: 0
address: 16499
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
- name: PV2Volt
unit_of_measurement: "V"
slave: 0
address: 16500
count: 1
precision: 1
scale: 1
data_type: uint16
device_class: voltage
scan_interval: 1
- name: PV2Current
unit_of_measurement: "A"
slave: 0
address: 16501
count: 1
precision: 2
scale: 1
data_type: uint16
device_class: current
scan_interval: 1
- name: PV2Power
unit_of_measurement: "W"
slave: 0
address: 16502
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
# 16503 and on gives 0xFFFF and 0
# 16525: 2313 (Voltage?)
# 16528: 1184 (Watt?)
# 16529: 2299 (Voltage?)
# 16530: 401 (Watt?)
# 16531: 2304 (Voltage?)
# 16532: 1283 (Watt?)
- name: PV_direction
slave: 0
address: 16533
count: 1
precision: 0
scale: 1
data_type: int16
scan_interval: 1
- name: Battery_direction
slave: 0
address: 16534
count: 1
precision: 0
scale: 1
data_type: int16
scan_interval: 1
- name: Grid_direction
slave: 0
address: 16535
count: 1
precision: 0
scale: 1
data_type: int16
scan_interval: 1
- name: Inverter_direction
slave: 0
address: 16536
count: 1
precision: 0
scale: 1
data_type: int16
scan_interval: 1
# 0x4099
- name: PVconsumptiontohouseFIXME
unit_of_measurement: "W"
slave: 0
address: 16537
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: GridconsumptionFIXME
unit_of_measurement: "W"
slave: 0
address: 16538
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: GridfeedinfromPV
unit_of_measurement: "W"
slave: 0
address: 16539
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: Gridfeedinfrombattery
unit_of_measurement: "W"
slave: 0
address: 16540
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: BatconsumptiontohouseFIXME
unit_of_measurement: "W"
slave: 0
address: 16541
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: BatchargingfromPV
unit_of_measurement: "W"
slave: 0
address: 16542
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: Batchargingfromgrid
unit_of_measurement: "W"
slave: 0
address: 16543
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: Systemtotalloadpower
unit_of_measurement: "W"
slave: 0
address: 16544
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
# This is what is bought from grid?
- name: Gridtotalpower
unit_of_measurement: "W"
slave: 0
address: 16545
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: PVtotalpower
unit_of_measurement: "W"
slave: 0
address: 16549
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: Batterytotalpower
unit_of_measurement: "W"
slave: 0
address: 16550
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: InverterTotalGridpowerFIXME
# 0x40A7 16551 This seems to be difference between Battery_power and Batterytotalpower, changed to 16551
# 40A7H 1 TotalGridPowerWatt Int16 0 W R The total active power of the grid
# SHould rather be named
unit_of_measurement: "W"
slave: 0
address: 16551
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
# This seems to be Bat+PV power
- name: Invertertotalpower
# 40A9H 16553 1 TotalInvPowerWatt Int16 0 W R Inverter total active power
unit_of_measurement: "W"
slave: 0
address: 16553
count: 1
precision: 0
scale: 1
data_type: int16
device_class: power
scan_interval: 1
- name: BackupTotalLoadPower
unit_of_measurement: "W"
slave: 0
address: 16555
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
- name: BackupTotalLoadPowerVA
unit_of_measurement: "VA"
slave: 0
address: 16556
count: 1
precision: 0
scale: 1
data_type: uint16
device_class: power
scan_interval: 1
- name: Today_pvenergy
unit_of_measurement: "kWh"
slave: 0
address: 16575
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
state_class: total_increasing
- name: Month_pvenergy
unit_of_measurement: "kWh"
slave: 0
address: 16577
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
state_class: total_increasing
- name: Year_pvenergy
unit_of_measurement: "kWh"
slave: 0
address: 16579
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
state_class: total_increasing
- name: Total_pvenergy
unit_of_measurement: "kWh"
slave: 0
address: 16581
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
state_class: total_increasing
- name: Today_batenergy
unit_of_measurement: "kWh"
slave: 0
address: 16583
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
state_class: total_increasing
- name: Month_batenergy
unit_of_measurement: "kWh"
slave: 0
address: 16585
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
- name: Year_batenergy
unit_of_measurement: "kWh"
slave: 0
address: 16587
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
- name: Total_batenergy
unit_of_measurement: "kWh"
slave: 0
address: 16589
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
- name: Today_batdischargeenergy
unit_of_measurement: "kWh"
slave: 0
address: 16591
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
state_class: total_increasing
- name: Month_batdischargeenergy
unit_of_measurement: "kWh"
slave: 0
address: 16593
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
- name: Year_batdischargeenergy
unit_of_measurement: "kWh"
slave: 0
address: 16595
count: 2
precision: 2
scale: 1
data_type: int32
device_class: energy
scan_interval: 100
- name: Total_batdischargeenergy
unit_of_measurement: "kWh"
slave: 0
address: 16597
count: 2
precision: 2
scale: 1
data_type: int32
device_class: energy
scan_interval: 100
- name: Today_InvGenEnergy
unit_of_measurement: "kWh"
slave: 0
address: 16599
count: 2
precision: 2
scale: 1
data_type: int32
device_class: energy
scan_interval: 100
- name: Month_InvGenEnergy
unit_of_measurement: "kWh"
slave: 0
address: 16601
count: 2
precision: 2
scale: 1
data_type: int32
device_class: energy
scan_interval: 100
- name: Year_InvGenEnergy
unit_of_measurement: "kWh"
slave: 0
address: 16603
count: 2
precision: 2
scale: 1
data_type: int32
device_class: energy
scan_interval: 100
- name: Total_InvGenEnergy
unit_of_measurement: "kWh"
slave: 0
address: 16605
count: 2
precision: 2
scale: 1
data_type: int32
device_class: energy
scan_interval: 100
- name: Today_pvconsumed_energy
unit_of_measurement: "kWh"
slave: 0
address: 16639
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
state_class: total_increasing
- name: Month_pvconsumed_energy
unit_of_measurement: "kWh"
slave: 0
address: 16641
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
- name: Year_pvconsumed_energy
unit_of_measurement: "kWh"
slave: 0
address: 16643
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
- name: Total_pvconsumed_energy
unit_of_measurement: "kWh"
slave: 0
address: 16645
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
- name: Today_gridconsumed_energy
unit_of_measurement: "kWh"
slave: 0
address: 16647
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100
state_class: total_increasing
- name: Month_gridconsumed_energy
unit_of_measurement: "kWh"
slave: 0
address: 16649
count: 2
precision: 2
scale: 1
data_type: uint32
device_class: energy
scan_interval: 100