Skip to content

Visual evoked potential and psychophysical contrast thresholds in glaucoma #96

Open
@jinglescode

Description

@jinglescode

Paper

Link: https://www.researchgate.net/publication/260683207_Visual_evoked_potential_and_psychophysical_contrast_thresholds_in_glaucoma
Year: 2014

Summary

  • 78 subjects
  • VEP and Psyc thresholds can be quite uncorrelated with glaucoma, the two types of thresholds contain independent information about glaucoma that could be usefully combined

Learnings

  • psychophysical studies of contrast thresholds revealed that testing at temporal frequencies (TF) of 8–10 Hz and spatial frequencies (SF) B1 cpd had good sensitivity for glaucoma
  • low SF stimuli modulated at somewhat higher TF, such that they displayed the frequency doubling (FD) illusion, were reported to provide improved ability to diagnose glaucoma
  • low spatial frequencies (<0.25 cpd) and high temporal frequencies (20–23 Hz) have been reported to be somewhat non-monotonic