Script to retrieve current Solar PV data from the Solarman API, and send Power (W) and Energy (kWh) metrics to a MQTT broker, for further use in home automation. Several PV vendors use the Solarman Smart platform for statistics, like sofar inverter with logger.
usage: solarman.py [--repeat]
Collect data from Solarman API
optional arguments:
--repeat Repeat at every interval defined in the config
You can run this script as a Docker container or in Python 3. Either way a configuration file is required. See the sample config.sample.json
file in this repository for reference. Also, a Solarman API appid and secret is required, which can be requested via mailto:service@solarmanpv.com.
Supported platforms:
- linux/amd64
- linux/386
- linux/arm/v7
- linux/arm/v6
- linux/arm64
Docker example to run this script every 5 minutes and providing a config file:
cd /opt
git clone https://github.com/hareeshmu/solarman
cd solarman
mv config.sample.json config.json # setup your config
sudo docker run --name solarman -d --restart unless-stopped -v /YOUR/PATH/HERE/config.json:/config.json hareeshmu/solarman:latest
This docker-compose.yml
example can be used with docker-compose or podman-compose
version: "3.7"
services:
solarman:
image: hareeshmu/solarman:latest
container_name: solarman
environment:
- PUID=1000
- PGID=1000
volumes:
- /YOUR/PATH/HERE/config.json:/config.json
restart: unless-stopped
Run pip install -r requirements.txt
and start python3 solarman.py
.
Run pip install -r requirements.txt
and start python3 solarman.py --repeat
.
solarmanpv/station/batteryPower
solarmanpv/station/batterySoc
solarmanpv/station/chargePower
solarmanpv/station/dischargePower
solarmanpv/station/generationPower
solarmanpv/station/gridPower
solarmanpv/station/irradiateIntensity
solarmanpv/station/lastUpdateTime
solarmanpv/station/purchasePower
solarmanpv/station/usePower
solarmanpv/station/wirePower
solarmanpv/inverter/deviceId
solarmanpv/inverter/deviceSn
solarmanpv/inverter/deviceState
solarmanpv/inverter/deviceType
solarmanpv/inverter/attributes # contains all inverter datalist entries.
SN: XXXXXXXXXX
Device_Type: 4
Production_Compliance_Type: 0
Rated_Power: 300.00
Year: 48
Month: 0
Day: 0
Hour: 0
Minute: 0
Seconds: 0
Communication_Protocol_Version: V0.2.0.1
Control_Board_Firmware_Version: V0.1.1.2
Communication_Board_Firmware_Version: V0.2.0.7
DC_Voltage_PV1: 0.00
DC_Voltage_PV2: 0.00
DC_Voltage_PV3: 0.00
DC_Voltage_PV4: 0.00
DC_Current_PV1: 0.00
DC_Current_PV2: 0.00
DC_Current_PV3: 0.00
DC_Current_PV4: 0.00
DC_Power_PV1: 0.00
DC_Power_PV2: 0.00
DC_Power_PV3: 0.00
DC_Power_PV4: 0.00
AC_Voltage_1: 0.00
AC_Current_1: 0.00
Total_AC_Output_Power(Active): 0
AC_Output_Frequency_1: 0.00
Total_Production(Active): 2.50
Total_Production_1: 2.50
Total_Production_2: 0.00
Total_Production_3: 0.00
Total_Production_4: 0.00
Daily_Production(Active): 0.70
Daily_Production_1: 0.70
Daily_Production_2: 0.00
Daily_Production_3: 0.00
Daily_Production_4: 0.00
AC_Radiator_Temp: -10.00
Micro_Inverter_Port_1: XXXXXXXXXX-1
Micro_Inverter_Port_2: XXXXXXXXXX-2
Micro_Inverter_Port_3: XXXXXXXXXX-3
Micro_Inverter_Port_4: XXXXXXXXXX-4
Number_Of_MPPT_Paths: 1
Number_Of_Phases: 1
Running_Status: 4
Overfrequency_And_Load_Reduction_Starting_Point: 50.20
Islanding Protection Enabled: Enable
Overfrequency_And_Load_Reduction_Percentage: 44
GFDI Enabled: Disable
Grid-connected Standard: 0
Grid Voltage_Upper_Limit: 275.00
Grid Voltage_Lower_Limit: 180.00
Grid Frequency_Upper_Limit: 52.00
Grid Frequency_Lower_Limit: 47.50
Start-up Self-checking Time: 60
solarmanpv/logger/deviceId
solarmanpv/logger/deviceSn
solarmanpv/logger/deviceState
solarmanpv/logger/deviceType
solarmanpv/logger/attributes # contains all logger datalist entries
Embedded_Device_SN: XXXXXXXXXX
Module_Version_No: MW3_15_5406_1.35
Extended_System_Version: V1.1.00.07
Total_running_time: 1
Offset_time: 1634486607
Data_Uploading_Period: 5
Data_Acquisition_Period: 60
Max._No._of_Connected_Devices: 1
Signal_Strength: 100
Heart_Rate: 120
IV_Curve_Supported: 1
Batch_Command_Supported: 1
Support_Reporting_Upgrading_Progress: 0
AT+UPGRADE_Command_Supported: 255
Method_Of_Protocol_Upgrade: 255
sensor:
- platform: mqtt
name: "solarmanpv_station_generationPower"
state_topic: "solarmanpv/station/generationPower"
unit_of_measurement: "W"
state_class: measurement
Repeat for every station topic needed.
sensor:
- platform: mqtt
name: "solarmanpv_inverter"
state_topic: "solarmanpv/inverter/deviceState"
json_attributes_topic: "solarmanpv/inverter/attributes"
- platform: mqtt
name: "solarmanpv_logger"
state_topic: "solarmanpv/logger/deviceState"
json_attributes_topic: "solarmanpv/logger/attributes"
- platform: template
sensors:
solarmanpv_inverter_device_state:
entity_id: sensor.solarmanpv_inverter
value_template: >-
{% set mapper = {
'1' : 'Online',
'2' : 'Failure',
'3' : 'Offline'} %}
{% set state = states.sensor.solarmanpv_inverter.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
- platform: template
sensors:
solarmanpv_logger_device_state:
entity_id: sensor.solarmanpv_logger
value_template: >-
{% set mapper = {
'1' : 'Online',
'2' : 'Failure',
'3' : 'Offline'} %}
{% set state = states.sensor.solarmanpv_logger.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
template:
- sensor:
- name: solarmanpv_inverter_dc_voltage_pv1
unit_of_measurement: 'V'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_current_pv1
unit_of_measurement: 'A'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_power_pv1
unit_of_measurement: 'W'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_power_pv1
unit_of_measurement: 'W'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_total_production_1
unit_of_measurement: 'kWh'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'Total_Production_1') }}"
state_class: total_increasing
- sensor:
- name: solarmanpv_inverter_daily_production_1
unit_of_measurement: 'kWh'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'Daily_Production_1') }}"
state_class: total_increasing
- sensor:
- name: solarmanpv_inverter_ac_radiator_temp
unit_of_measurement: '°C'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Radiator_Temp') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_voltage_1
unit_of_measurement: 'V'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_current_1
unit_of_measurement: 'A'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_output_frequency_1
unit_of_measurement: 'Hz'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Output_Frequency_1') }}"
state_class: measurement