-
Notifications
You must be signed in to change notification settings - Fork 84
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
HP ssacli - rebuilding shouldn't perhaps still be warning state? #212
Comments
|
|
|
|
|
Bonjour, I have the same issue with a P408i-a. In rebuid state the output of the plugin was In the file hpacucli.pm, I change the ligne } elsif ($s eq 'Rebuild' or $s eq 'Recover') { Maybe just change the line to } elsif ($s eq 'Rebuild' or $s =~ 'Recover') { can also work. There is probably a better way to do it. Hope that fix also your problem Regards, Frederic |
Hey.
This is the very same system as described in #211... i.e. the same failed drive, output, etc..
After marking the predictively failed disk (which is actually completely broken and the controller doesn't just get it... o.O), and rebooting the system, HP Smart Array started with an auto rebuild.
check_raid
outputs here the following:I.e. it gives
OK
while it's actually still rebuilding.I think it would be better, if in that state it would still give a
WARNING
, because it's not yet clear whether the rebuild succeeds - e.g. with this bogus drive, it definitely won't (the drive is suuuuuuper slow... I'd be dead before any rebuild had finished).Following, some
ssacli
output while rebuilding, just if that helps:The text was updated successfully, but these errors were encountered: