#!/usr/bin/env python3
#############################################################################
################### Helper Library of Domoticz conversions ##################
#############################################################################
#
# It's heavily based on ESPEasy library, thanks for it!
#
# Copyright (C) 2018-2019 by Alexander Nagy - https://bitekmindenhol.blog.hu/
#
import rpieGlobals
import linux_os as OS
import time
import misc
_lastRSSIval = 0
_lastRSSItime = 0
def humStatDomoticz(humidity):
res=3
try:
hum = int(humidity)
if (hum<30):
res=2
elif (hum<40):
res=0
elif (hum<59):
res=1
except:
pass
return str(res)
def mapRSSItoDomoticz(urssi=-1):
global _lastRSSIval, _lastRSSItime
res = 12
if ((time.time()-_lastRSSItime)>=3) and (urssi==-1):
_lastRSSIval = OS.get_rssi()
_lastRSSItime = time.time()
try:
if urssi != -1:
rssi = urssi
else:
rssi = int(_lastRSSIval)
if (-50<rssi):
res = 10
elif (rssi<= -98):
res = 0
else:
res = int(round((rssi+97)/5,0)+1)
except:
pass
return str(res)
def formatDomoticzSensorType(sensortype,valuearr):
valuestr = ""
if (sensortype==rpieGlobals.SENSOR_TYPE_SINGLE) or (sensortype==rpieGlobals.SENSOR_TYPE_TEXT):
valuestr += str(valuearr[0]).strip()
elif (sensortype==rpieGlobals.SENSOR_TYPE_LONG):
valuestr += str(valuearr[0] + (valuearr[1] << 16)).strip()
elif (sensortype==rpieGlobals.SENSOR_TYPE_DUAL):
valuestr += str(valuearr[0]).strip() + ";" + str(valuearr[1]).strip()
elif (sensortype==rpieGlobals.SENSOR_TYPE_TEMP_HUM):
valuestr += str(valuearr[0]).strip() + ";" + str(valuearr[1]).strip()+ ";" + humStatDomoticz(valuearr[1])
elif (sensortype==rpieGlobals.SENSOR_TYPE_TEMP_HUM_BARO):
valuestr += str(valuearr[0]).strip() + ";" + str(valuearr[1]).strip()+ ";" + humStatDomoticz(valuearr[1])
valuestr += ";"+str(valuearr[2]).strip() + ";0"
elif (sensortype==rpieGlobals.SENSOR_TYPE_TEMP_BARO):
valuestr += str(valuearr[0]).strip() + ";" + str(valuearr[1]).strip()
valuestr += ";0;0"
elif (sensortype==rpieGlobals.SENSOR_TYPE_TEMP_EMPTY_BARO):
valuestr += str(valuearr[0]).strip() + ";" + str(valuearr[2]).strip()
valuestr += ";0;0"
elif (sensortype==rpieGlobals.SENSOR_TYPE_TRIPLE):
valuestr += str(valuearr[0]).strip() + ";" + str(valuearr[1]).strip()
valuestr += ";"+str(valuearr[2]).strip()
elif (sensortype==rpieGlobals.SENSOR_TYPE_QUAD):
valuestr += str(valuearr[0]).strip() + ";" + str(valuearr[1]).strip()
valuestr += ";"+str(valuearr[2]).strip()+";"+str(valuearr[3]).strip()
elif (sensortype==rpieGlobals.SENSOR_TYPE_SWITCH) or (sensortype==rpieGlobals.SENSOR_TYPE_DIMMER):
pass # Too specific for HTTP/MQTT
else:
misc.addLog(rpieGlobals.LOG_LEVEL_ERROR,"Domoticz Controller: Not yet implemented sensor type: "+sensortype)
return valuestr