To support "Loading from grid" the „Working Mode“, Register 13895 (3647H) must be changed from backup_mode (2) to time_mode (1) while some other register (start and end time and loading power) can be set to fixed values either via modbus or via "ampere.home" App local connection or "eSolar O&M" App loacal connection.
I tested this on my site and it's working. @dboeni, you can contact me via u.dicke@gmx.de for further informations
To support "Loading from grid" the „Working Mode“, Register 13895 (3647H) must be changed from backup_mode (2) to time_mode (1) while some other register (start and end time and loading power) can be set to fixed values either via modbus or via "ampere.home" App local connection or "eSolar O&M" App loacal connection.
I tested this on my site and it's working. @dboeni, you can contact me via u.dicke@gmx.de for further informations
H2-3~6K-S2 single phase communication protocol -2022.12.02-EN_schreibbare_Register.pdf
Ampere.Storage.Pro is SAJ-H2 with a new label.