Notifications
You must be signed in to change notification settings - Fork 34
/
Copy pathsolis_hybrid.yaml
944 lines (862 loc) · 24 KB
/
solis_hybrid.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
#
# Solis RHI-1P3~6K-48ES-5G | 3~6kW | Single Phase | Hybrid Inverter
#
# Reference: https://github.com/user-attachments/files/16650051/RS485_MODBUS-Hybrid-BACoghlan-201811228-1854.pdf
#
# Tested
#
default:
update_interval: 10
code: 0x04
min_span: -1
max_size: 100
digits: 6
requests:
- start: 43000
end: 43300
code: 0x03
parameters:
- group: InverterStatus
items:
- name: "Inverter Status"
rule: 1
registers: [33095]
icon: "mdi:home-lightning-bolt"
lookup:
- key: 0x0
value: "Waiting State"
- key: 0x1
value: "Open Loop Operation"
- key: 0x2
value: "Soft Start"
- key: 0x3
value: "On Grid/Generating"
- key: 0x1004
value: "Grid OverVoltage"
- key: 0x1010
value: "Grid UnderVoltage"
- key: 0x1012
value: "Grid OverFrequency"
- key: 0x1013
value: "Grid UnderFrequency"
- key: 0x1014
value: "Grid Imp too large"
- key: 0x1015
value: "No Grid"
- key: 0x1016
value: "Grid Imbalance"
- key: 0x1017
value: "Grid Freq Jitter"
- key: 0x1018
value: "Grid Overcurrent"
- key: 0x1019
value: "Grid Tracking Fault"
- key: 0x1020
value: "DC OverVoltage"
- key: 0x1021
value: "DC Bus Overvoltage"
- key: 0x1022
value: "DC Bus Uneven Voltage"
- key: 0x1024
value: "DC Bus Uneven Voltage2"
- key: 0x1025
value: "DC A path OverCurrent"
- key: 0x1026
value: "DC B path OverCurrent"
- key: 0x1027
value: "DC Input Disturbance"
- key: 0x1030
value: "Grid Disturbance"
- key: 0x1031
value: "DSP Initialization Protection"
- key: 0x1032
value: "Over Temp Protection"
- key: 0x1033
value: "PV Insulation Fault"
- key: 0x1034
value: "Leakage Current Protection"
- key: 0x1035
value: "Relay Detection Protection"
- key: 0x1036
value: "DSP_B Protection"
- key: 0x1037
value: "DC Component too Large"
- key: 0x1038
value: "12v UnderVoltage Protection"
- key: 0x1039
value: "Under Temperature Protection"
- key: 0x1040
value: "Arc Self-Test Protection"
- key: 0x1041
value: "Arc Protection"
- key: 0x1042
value: "DSP on-chip SRAM exception"
- key: 0x1043
value: "DSP on-chip FLASH exception"
- key: 0x1044
value: "DSP on-chip PC pointer is abnormal"
- key: 0x1045
value: "DSP key register exception"
- key: 0x1046
value: "Grid disturbance 02"
- key: 0x1047
value: "Grid current sampling abnormality"
- key: 0x1048
value: "IGBT overcurrent"
- key: 0x1050
value: "Network current transient overcurrent"
- key: 0x1051
value: "Battery overvoltage hardware failure"
- key: 0x1052
value: "LLC hardware overcurrent"
- key: 0x1053
value: "Battery overvoltage detection"
- key: 0x1054
value: "Battery undervoltage detection"
- key: 0x1055
value: "Battery no connected"
- key: 0x1056
value: "Bypass overvoltage fault"
- key: 0x1057
value: "Bypass overload fault"
- name: "Operating Status"
rule: 1
registers: [33121]
icon: "mdi:home-lightning-bolt"
lookup:
- key: 0x701
value: "Normal Operation"
- key: 0x702
value: "Initial Standby"
- key: 0x704
value: "Control Shutdown"
- key: 0x708
value: "Downtime"
- key: 0x710
value: "Standby"
- key: 0x720
value: "Derating Operation"
- key: 0x740
value: "Limit Operation"
- key: 0x780
value: "Bypass Overload"
- name: "Grid Fault Status"
rule: 1
registers: [33116]
icon: "mdi:alert"
lookup:
- key: 0x0000
value: "No Fault"
- key: 0x1
value: "No Grid"
- key: 0x2
value: "Grid OverVoltage"
- key: 0x4
value: "Grid UnderVoltage"
- key: 0x8
value: "Grid OverFrequency"
- key: 0x10
value: "Grid UnderFrequency"
- key: 0x20
value: "Grid Imbalance"
- key: 0x40
value: "Grid Frequncy Jitter"
- key: 0x80
value: "Grid Impedence too Large"
- key: 0x100
value: "Grid Tracking Fault"
- key: 0x200
value: "Meter Comm Failure"
- key: 0x400
value: "Failsafe"
- name: "Backup Load Fault Status"
rule: 1
registers: [33117]
icon: "mdi:alert"
lookup:
- key: 0x0
value: "No Fault"
- key: 0x1
value: "Bypass OverVoltage Fault"
- key: 0x2
value: "Bypass Overload Fault"
- name: "Battery Fault Status"
rule: 1
registers: [33118]
icon: "mdi:alert"
lookup:
- key: 0x0
value: "No Fault"
- key: 0x1
value: "Battery Not Connected"
- key: 0x2
value: "Battery OverVoltage Detection"
- key: 0x4
value: "Battery UnderVoltage Detection"
- name: "Fault Status 04 (Device)"
rule: 1
registers: [33119]
icon: "mdi:alert"
lookup:
- key: 0x0000
value: "No Fault"
- key: 0x1
value: "DC OverVoltage"
- key: 0x2
value: "DC Bus OverVoltage"
- key: 0x4
value: "DC Bus Uneven Voltage"
- key: 0x8
value: "DC Bus UnderVoltage"
- key: 0x10
value: "DC Bus2 Uneven Voltage"
- key: 0x20
value: "DC A path OverCurrent"
- key: 0x40
value: "DC B path OverCurrent"
- key: 0x80
value: "DC Input Disturbance"
- key: 0x100
value: "Grid OverCurrent"
- key: 0x200
value: "IGBT OverCurrent"
- key: 0x400
value: "Grid Disturbance 2"
- key: 0x800
value: "Arc Self-Test Protection"
- key: 0x1000
value: "Arc Fault Reservation"
- key: 0x2000
value: "Grid Current Sample Abnormality"
- name: "Fault Status 05 (Device)"
rule: 1
registers: [33120]
icon: "mdi:alert"
lookup:
- key: 0x0000
value: "No Fault"
- key: 0x1
value: "Grid Disturbance"
- key: 0x2
value: "DC Component Too Large"
- key: 0x4
value: "Over Temp Protection"
- key: 0x8
value: "Relay Detection Protection"
- key: 0x10
value: "Under Temp Protection"
- key: 0x20
value: "PV Insulation Fault"
- key: 0x40
value: "12V UnderVoltage Protection"
- key: 0x80
value: "Leakage Current Protection"
- key: 0x100
value: "Leakage Current Self-Test"
- key: 0x200
value: "DSP Initialization Protect"
- key: 0x400
value: "DSP B Protection"
- key: 0x800
value: "Battery Overvoltage H/W Failure"
- key: 0x1000
value: "LLC Hardware OverCurrent"
- key: 0x2000
value: "Network Side Transient OverCurrent"
- key: 0x4000
value: "CAN Communication Failed"
- key: 0x8000
value: "DSP Communication Failed"
- name: "Date & Time"
platform: datetime
update_interval: 60
rule: 8
registers: [33022, 33023, 33024, 33025, 33026, 33027]
- name: "Temperature"
class: "temperature"
state_class: "measurement"
uom: "°C"
scale: 0.1
rule: 2
registers: [33093]
icon: "mdi:thermometer"
# Sensors below are outside of modbus request ranges.
# If enabling, ensure to amend the request start register.
#
# - name: "Inverter ID"
# rule: 5
# registers: [33004,33005,33006,33007,33008,33009,33010,33011,33012,33013,33014,33015,33016,33017,33018,33019]
# - name: "Product Model"
# rule: 6
# registers: [33000]
# - name: "DSP Software Version"
# rule: 6
# registers: [33001]
# - name: "LCD Software Version"
# rule: 6
# registers: [33002]
# - name: "Protocol Software Version"
# rule: 6
# registers: [33003]
- name: "Storage Control Mode"
rule: 1
registers: [33132]
icon: "mdi:battery-clock"
lookup:
- key: 0x0000
value: "Disabled"
- key: 0x0021
value: "Self Use"
- key: 0x0022
value: "Optimized Revenue"
- key: 0x0023
value: "Time of Use"
- key: 0x0024
value: "Off-Grid"
- key: 0x0028
value: "Battery Wake-Up"
- key: 0x0031
value: "Backup"
- key: 0x0060
value: "Feed-In Priority"
- group: InverterDC
items:
- name: "PV1 Voltage"
class: "voltage"
mppt: 1
state_class: "measurement"
uom: "V"
scale: 0.1
rule: 1
registers: [33049]
icon: "mdi:solar-power"
- name: "PV2 Voltage"
class: "voltage"
mppt: 2
state_class: "measurement"
uom: "V"
scale: 0.1
rule: 1
registers: [33051]
icon: "mdi:solar-power"
- name: "PV1 Current"
class: "current"
mppt: 1
uom: "A"
scale: 0.1
rule: 1
registers: [33050]
icon: "mdi:current-dc"
- name: "PV2 Current"
class: "current"
mppt: 2
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 1
registers: [33052]
icon: "mdi:current-dc"
- name: "Inverter DC Power"
class: "power"
state_class: "measurement"
uom: "W"
rule: 3
registers: [33058, 33057]
icon: "mdi:solar-power"
- name: "Inverting/Rectifing Power"
class: "power"
state_class: "measurement"
uom: "W"
scale: 10
rule: 2
registers: [33157]
icon: "mdi:solar-power"
- group: InverterAC
items:
- name: "Inverter AC Power"
class: "power"
state_class: "measurement"
uom: "W"
rule: 4
registers: [33152, 33151]
icon: "mdi:solar-power"
- name: "Inverter Voltage"
class: "voltage"
state_class: "measurement"
uom: "V"
scale: 0.1
rule: 1
registers: [33073]
icon: "mdi:transmission-tower"
- name: "Inverter Current"
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 1
registers: [33076]
icon: "mdi:current-ac"
- name: "Inverter Active Power"
class: "power"
state_class: "measurement"
uom: "W"
rule: 4
registers: [33080, 33079]
icon: "mdi:transmission-tower"
# Inverter Reactive Power is defined as a signed 32 bit integer
# across 33082 and 33081, however the field appears to be only
# 20 bits wide i.e. the upper 12 bits are always zero.
# Define only the lower signed 16 bits for moment
- name: "Inverter Reactive Power"
class: "reactive_power"
state_class: "measurement"
uom: "var"
rule: 4
registers: [33082]
icon: "mdi:transmission-tower"
- name: "Inverter Apparent Power"
class: "apparent_power"
state_class: "measurement"
uom: "VA"
rule: 4
registers: [33084, 33083]
icon: "mdi:transmission-tower"
- name: "Inverter Frequency"
class: "frequency"
state_class: "measurement"
uom: "Hz"
scale: 0.01
rule: 1
registers: [33094]
icon: "mdi:sine-wave"
- group: Production
items:
- name: "Today Production"
friendly_name: Today's Production
class: "energy"
state_class: "total_increasing"
uom: "kWh"
scale: 0.1
rule: 1
registers: [33035]
icon: "mdi:solar-power"
- name: "Monthly Production"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
rule: 3
registers: [33032, 33031]
icon: "mdi:solar-power"
- name: "Yearly Production"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
rule: 3
registers: [33038, 33037]
icon: "mdi:solar-power"
- name: "Total Production"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
rule: 3
registers: [33030, 33029]
icon: "mdi:solar-power"
validation:
min: 0.1
- group: Grid
items:
- name: "Meter Frequency"
class: "frequency"
state_class: "measurement"
uom: "Hz"
scale: 0.01
rule: 1
registers: [33282]
icon: "mdi:sine-wave"
- name: "Meter Power Factor"
class: "power_factor"
state_class: "measurement"
scale: 0.01
rule: 2
registers: [33281]
icon: "mdi:transmission-tower"
- name: "Meter Voltage"
class: "voltage"
state_class: "measurement"
uom: "V"
scale: 0.1
rule: 1
registers: [33251]
icon: "mdi:transmission-tower"
- name: "Meter Current"
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.01
rule: 1
registers: [33252]
icon: "mdi:current-ac"
- name: "Meter Active Power"
class: "power"
state_class: "measurement"
uom: "W"
rule: 4
registers: [33258, 33257]
icon: "mdi:transmission-tower"
- name: "Meter Reactive Power"
class: "reactive_power"
state_class: "measurement"
uom: "var"
rule: 4
registers: [33266, 33265]
icon: "mdi:transmission-tower"
- name: "Meter Apparent Power"
class: "apparent_power"
state_class: "measurement"
uom: "VA"
rule: 4
registers: [33274, 33273]
icon: "mdi:transmission-tower"
- name: "Today Energy Import"
friendly_name: "Today's Energy Import"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
scale: 0.1
rule: 1
registers: [33171]
icon: "mdi:home-import-outline"
- name: "Total Energy Import"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
rule: 3
registers: [33170, 33169]
icon: "mdi:home-import-outline"
validation:
min: 0.1
- name: "Today Energy Export"
friendly_name: "Today's Energy Export"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
scale: 0.1
rule: 1
registers: [33175]
icon: "mdi:home-export-outline"
- name: "Total Energy Export"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
rule: 3
registers: [33174, 33173]
icon: "mdi:home-export-outline"
validation:
min: 0.1
- group: Load
items:
- name: "House Load Power"
class: "power"
state_class: "measurement"
uom: "W"
rule: 1
registers: [33147]
icon: "mdi:home-lightning-bolt"
- name: "Backup Load Power"
class: "power"
state_class: "measurement"
uom: "W"
rule: 1
registers: [33148]
icon: "mdi:home-battery"
- name: "Today Load Consumption"
friendly_name: "Today's Load Consumption"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
scale: 0.1
rule: 1
registers: [33179]
- name: "Total Load Consumption"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
rule: 3
registers: [33178, 33177]
validation:
min: 0.1
- group: Battery
items:
- name: "Battery State"
rule: 1
registers: [33135]
lookup:
- key: 0
value: "charging"
- key: 1
value: "discharging"
- key: "default"
value: "idle"
icon: "mdi:battery"
- name: "Battery Power"
class: "power"
state_class: "measurement"
uom: "W"
rule: 4
registers: [33150, 33149]
icon: "mdi:battery-charging"
- name: "Battery"
class: "battery"
state_class: "measurement"
uom: "%"
rule: 1
registers: [33139]
icon: "mdi:battery"
- name: "Battery SOH"
state_class: "measurement"
uom: "%"
rule: 1
registers: [33140]
icon: "mdi:battery"
- name: "Battery Current"
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 2
registers: [33134]
icon: "mdi:current-dc"
- name: "Battery Voltage"
class: "voltage"
state_class: "measurement"
uom: "V"
scale: 0.1
rule: 1
registers: [33133]
icon: "mdi:battery"
- name: "Today Battery Charge"
friendly_name: Today's Battery Charge
class: "energy"
state_class: "total_increasing"
uom: "kWh"
scale: 0.1
rule: 1
registers: [33163]
icon: "mdi:battery-plus"
- name: "Today Battery Discharge"
friendly_name: Today's Battery Discharge
class: "energy"
state_class: "total_increasing"
uom: "kWh"
scale: 0.1
rule: 1
registers: [33167]
icon: "mdi:battery-minus"
- name: "Total Battery Charge"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
rule: 3
registers: [33162, 33161]
icon: "mdi:battery-plus"
validation:
min: 0.1
- name: "Total Battery Discharge"
class: "energy"
state_class: "total_increasing"
uom: "kWh"
rule: 3
registers: [33166, 33165]
icon: "mdi:battery-minus"
validation:
min: 0.1
- name: "Battery Charge Current Limit"
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 1
registers: [33206]
icon: "mdi:battery-arrow-up"
- name: "Battery Discharge Current Limit"
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 1
registers: [33207]
icon: "mdi:battery-arrow-down"
- name: "BMS Battery Current"
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 2
registers: [33142]
icon: "mdi:current-dc"
- name: "BMS Battery Voltage"
class: "voltage"
state_class: "measurement"
uom: "V"
scale: 0.01
rule: 1
registers: [33141]
icon: "mdi:battery"
- name: "BMS Battery Charge Current Limit"
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 1
registers: [33143]
icon: "mdi:battery-arrow-up"
- name: "BMS Battery Discharge Current Limit"
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 1
registers: [33144]
icon: "mdi:battery-arrow-down"
- name: "Backup Mode SOC"
state_class: "measurement"
uom: "%"
rule: 1
registers: [43024]
icon: "mdi:battery"
- name: "Overdischarge SOC"
state_class: "measurement"
uom: "%"
rule: 1
registers: [43011]
icon: "mdi:battery"
- group: Time of Use
items:
- name: Storage Control Mode
platform: select
rule: 1
code:
read: 0x03
write: 0x06
registers: [43110]
lookup:
- key: 0x0000
value: "Disabled"
- key: 0x0021
value: "Self Use"
- key: 0x0022
value: "Optimized Revenue"
- key: 0x0023
value: "Time of Use"
- key: 0x0024
value: "Off-Grid"
- key: 0x0028
value: "Battery Wake-Up"
- key: 0x0031
value: "Backup"
- key: 0x0060
value: "Feed-In Priority"
- name: "Timed Charge Current"
plaform: number
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 1
registers: [43141]
configurable:
min: 0
max: 180
step: 0.1
range:
min: 0
max: 1800
icon: "mdi:wrench-clock"
- name: "Timed Discharge Current"
plaform: number
class: "current"
state_class: "measurement"
uom: "A"
scale: 0.1
rule: 1
registers: [43142]
configurable:
min: 0
max: 180
step: 0.1
range:
min: 0
max: 1800
icon: "mdi:wrench-clock"
- name: "Timed Charge Start"
platform: time
state_class: measurement
rule: 9
registers: [43143, 43144]
icon: "mdi:wrench-clock"
- name: "Timed Charge End"
platform: time
state_class: "measurement"
rule: 9
registers: [43145, 43146]
icon: "mdi:wrench-clock"
- name: "Timed Discharge Start"
platform: time
state_class: "measurement"
rule: 9
registers: [43147, 43148]
icon: "mdi:wrench-clock"
- name: "Timed Discharge End"
platform: time
state_class: "measurement"
rule: 9
registers: [43149, 43150]
icon: "mdi:wrench-clock"
- name: "Timed Charge 2 Start"
platform: time
state_class: measurement
rule: 9
registers: [43153, 43154]
icon: "mdi:wrench-clock"
- name: "Timed Charge 2 End"
platform: time
state_class: "measurement"
rule: 9
registers: [43155, 43156]
icon: "mdi:wrench-clock"
- name: "Timed Discharge 2 Start"
platform: time
state_class: "measurement"
rule: 9
registers: [43157, 43158]
icon: "mdi:wrench-clock"
- name: "Timed Discharge 2 End"
platform: time
state_class: "measurement"
rule: 9
registers: [43159, 43160]
icon: "mdi:wrench-clock"
- name: "Timed Charge 3 Start"
platform: time
state_class: measurement
rule: 9
registers: [43163, 43164]
icon: "mdi:wrench-clock"
- name: "Timed Charge 3 End"
platform: time
state_class: "measurement"
rule: 9
registers: [43165, 43166]
icon: "mdi:wrench-clock"
- name: "Timed Discharge 3 Start"
platform: time
state_class: "measurement"
rule: 9
registers: [43167, 43168]
icon: "mdi:wrench-clock"
- name: "Timed Discharge 3 End"
platform: time
state_class: "measurement"
rule: 9
registers: [43169, 43170]
icon: "mdi:wrench-clock"