Notifications
You must be signed in to change notification settings - Fork 0
/
cvc_globals.py
executable file
·118 lines (105 loc) · 5.4 KB
/
cvc_globals.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
"""cvc_globals: Definitions of global lists for check_cvc
The order of errors in errorList is the priority that the errors are displayed in.
The priorityMap is generated from errorList.
Functions:
InitializeErrors: Initialize error data from cvc_globals.
Copyright 2106 D. Mitch Bailey d.mitch.bailey at gmail dot com
This file is part of check_cvc.
check_cvc is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
check_cvc is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with check_cvc. If not, see <http://www.gnu.org/licenses/>.
You can download check_cvc from https://github.com/d-m-bailey/check_cvc.git
"""
import re
validLevels = ['ERROR', 'Warning', 'Check', 'ignore']
priorityMap = {} # section: priority
errorList = [ \
{'source': 'log', 'section': 'resistor',
'searchText': "^INFO: resistor voltage calculation"},
{'source': 'log', 'section': 'unsupported_device',
'searchText': "^WARNING: unsupported devices in netlist"},
{'source': 'log', 'section': 'min_voltage_ignore',
'searchText': "^WARNING: min voltage .* ignored for "},
{'source': 'log', 'section': 'max_voltage_ignore',
'searchText': "^WARNING: max voltage .* ignored for "},
{'source': 'log', 'section': 'unexpected_max_voltage',
'searchText': "^WARNING: Max voltage already set for"},
{'source': 'log', 'section': 'unexpected_min_voltage',
'searchText': "^WARNING: Min voltage already set for"},
{'source': 'log', 'section': 'unknown_max_gate',
'searchText': "^WARNING: unknown max gate at"},
{'source': 'log', 'section': 'unknown_min_gate',
'searchText': "^WARNING: unknown min gate at"},
{'source': 'log', 'section': 'fuse_only',
'searchText': "^WARNING: MIN = MAX .* through FUSE"},
{'source': 'log', 'section': 'resistor_error',
'searchText': "^WARNING: Could not calculate explicit resistor voltage"},
{'source': 'log', 'section': 'inverter_error',
'searchText': "^WARNING: could not set .* ->inv-> "},
{'source': 'log', 'section': 'port_min/max',
'searchText': "^WARNING: Invalid Min/Max on top level port"},
{'source': 'log', 'section': 'min_exceeds_sim',
'searchText': "^WARNING: MIN > SIM"},
{'source': 'log', 'section': 'sim_exceeds_max',
'searchText': "^WARNING: MAX < SIM"},
{'source': 'log', 'section': 'high_res_bias',
'searchText': "^WARNING: high res bias"},
{'source': 'log', 'section': 'missing_bias',
'searchText': "^WARNING: missing bias"},
{'source': 'log', 'section': 'missing_overvoltage',
'searchText': "^WARNING: no overvoltage check for model"},
{'source': 'log', 'section': 'possible_missing_input',
'searchText': "^WARNING: possible missing input at net"},
{'source': 'log', 'section': 'resistance_overflow',
'searchText': "^WARNING: resistance "},
{'source': 'log', 'section': 'unexpected_diode',
'searchText': "^INFO: unexpected diode"},
{'source': 'report', 'section': 'MOS_DIODE',
'searchText': "^! ... voltage already"},
{'source': 'report', 'section': 'SHORT',
'searchText': "^! Short Detected"},
{'source': 'report', 'section': 'BIAS',
'searchText': "^! Checking .mos source/drain vs bias errors"},
{'source': 'report', 'section': 'FORWARD',
'searchText': "^! Checking forward bias diode errors"},
{'source': 'report', 'section': 'FLOATING',
'searchText': "^! Checking mos floating input errors"},
{'source': 'report', 'section': 'GATE',
'searchText': "^! Checking .mos gate vs source errors"},
{'source': 'report', 'section': 'LEAK?',
'searchText': "^! Checking .mos possible leak errors"},
{'source': 'report', 'section': 'VALUE',
'searchText': "^! Checking expected values"},
{'source': 'report', 'section': 'LDD',
'searchText': "^! Checking LDD errors for model"},
{'source': 'report', 'section': 'OVERVOLTAGE_VBG',
'searchText': "^! Checking Vbg overvoltage errors"},
{'source': 'report', 'section': 'OVERVOLTAGE_VBS',
'searchText': "^! Checking Vbs overvoltage errors"},
{'source': 'report', 'section': 'OVERVOLTAGE_VDS',
'searchText': "^! Checking Vds overvoltage errors"},
{'source': 'report', 'section': 'OVERVOLTAGE_VGS',
'searchText': "^! Checking Vgs overvoltage errors"},
{'source': 'report', 'section': 'UNKNOWN',
'searchText': "^! Finished"}
]
def InitializeErrors():
"""Initialize error data from cvc_globals.
Modifies:
errorList - adds 'priority' and 'regex'
priorityMap - error section to priority map (priority is order in errorList)
"""
myIndex = 0
for myError in errorList:
myError['priority'] = myIndex
myError['regex'] = re.compile(myError['searchText'])
priorityMap[myError['section']] = myIndex
myIndex += 1