You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The Visca over IP backend does not work with Sony BRC cameras, the messages are missing the required header (Payload type/Payload length/Sequence number). See Sony VISCA over IP document page 10. https://pro.sony/support/res/manuals/C456/26213181c7ae83822c3124b5b3b836ee/C4561001M.pdf
Midimonster is just sending the "payload" part - this might wor with e.g. PTZOptics cameras, but not with Sony BRC or FR cameras.
Any chance this will be implemented? Maybe an extra backend for Sony PTZ?
The text was updated successfully, but these errors were encountered:
Thanks for your effort and including a link to the documentation! Unfortunately the VISCA specs are somewhat manufacturer-specific.
I'll try to investigate whether making an optional header transmission part of the original backend makes sense, otherwise it might be easier to do a separate backend while sharing some of the code.
The Visca over IP backend does not work with Sony BRC cameras, the messages are missing the required header (Payload type/Payload length/Sequence number). See Sony VISCA over IP document page 10.
https://pro.sony/support/res/manuals/C456/26213181c7ae83822c3124b5b3b836ee/C4561001M.pdf
Midimonster is just sending the "payload" part - this might wor with e.g. PTZOptics cameras, but not with Sony BRC or FR cameras.
Any chance this will be implemented? Maybe an extra backend for Sony PTZ?