ModBus Measurement Daemon
Easily read and distribute data from ModBus meters and grid inverters
-a, --adapter string Default MODBUS adapter. This option can be used if all devices are attached to a single adapter.
Can be either an RTU device (/dev/ttyUSB0) or TCP socket (localhost:502).
The default adapter can be overridden per device
-b, --baudrate int Serial interface baud rate (default 9600)
--comset string Communication parameters for default adapter, either 8N1 or 8E1.
Only applicable if the default adapter is an RTU device (default "8N1")
-c, --config string Config file (default is $HOME/mbmd.yaml)
-h, --help Help for mbmd
--raw Log raw device data
--rtu Use RTU over TCP for default adapter.
Typically used with RS485 to Ethernet adapters that don't perform protocol conversion (e.g. USR-TCP232).
Only applicable if the default adapter is a TCP connection
-v, --verbose Verbose mode
- mbmd inspect - Inspect SunSpec device models and implemented values
- mbmd read - Read register (EXPERIMENTAL)
- mbmd run - Read and publish measurements from all configured devices
- mbmd scan - Scan for attached devices
- mbmd version - Show MBMD version
- mbmd write - Write register (EXPERIMENTAL)