You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
We have yet another obscure error and are forced to ask for help. Spent quite a few weeks trying to diagnose the problem that happens on a particular drive. We have so far been able to run SOEM on multiple brands.
Posting the Wireshark for both SOEM(not working) and Twin CAT ( working ) WireShark.zip
The drive goes into safe op but errors out immediately due to work counter being 0.
Any advice is much appreciated.
The text was updated successfully, but these errors were encountered:
Your slave is using 1-buffer system for PDO. Therefore it must be used in DC sync mode. You have to prepare the master to cope with this. There are strict rules to work by. Your test code is not going to work. Read #487 (comment)
We have yet another obscure error and are forced to ask for help. Spent quite a few weeks trying to diagnose the problem that happens on a particular drive. We have so far been able to run SOEM on multiple brands.
Posting the Wireshark for both SOEM(not working) and Twin CAT ( working ) WireShark.zip
The drive goes into safe op but errors out immediately due to work counter being 0.
Any advice is much appreciated.
The text was updated successfully, but these errors were encountered: