Open
Description
I am extending the default BLOM system test suite to cover all pre-defined compsets. There run fails when testing NOIIAOC20TR
, in mo_carchm
.
103: forrtl: error (75): floating point exception
103: Image PC Routine Line Source
103: cesm.exe 0000000004A6E2CB Unknown Unknown Unknown
103: libc.so.6 000014A3C7454DB0 Unknown Unknown Unknown
103: cesm.exe 00000000043EE593 mo_carchm_mp_carc 985 mo_carchm.F90
103: cesm.exe 00000000043A5523 mo_carchm_mp_carc 454 mo_carchm.F90
103: cesm.exe 0000000003FFFC15 mo_hamocc4bcm_mp_ 256 mo_hamocc4bcm.F90
103: cesm.exe 000000000367708F mo_hamocc_step_mp 83 mo_hamocc_step.F90
103: cesm.exe 000000000357360A mod_tracers_updat 163 mod_tracers_update.F90
103: cesm.exe 0000000002CA346B mod_blom_step_mp_ 230 mod_blom_step.F90
103: cesm.exe 0000000002C2EB2C ocn_comp_nuopc_mp 910 ocn_comp_nuopc.F90
Line 985: subroutine carchm_solve_dicsat
ah2o = sqrt((K1*co2_sat)**2 + 4.*ac*2.*K1*k2*co2_sat)
It is strange that the NOIIAOC
compset does not fail. The difference is
<alias>NOIIAOC</alias>
<lname>2000_DATM%IAF_SLND_CICE_BLOM%HYB%ECO_DROF%IAF_SGLC_SWAV</lname>
...
<alias>NOIIAOC20TR</alias>
<lname>20TR_DATM%IAF_SLND_CICE_BLOM%HYB%ECO_DROF%IAF_SGLC_SWAV</lname>
...
<entry id="RUN_STARTDATE">
compset="20TR_DATM%IAF_SLND_CICE_BLOM%HYB%ECO_DROF%IAF_SGLC_SWAV">1700-01-01</value>
Metadata
Metadata
Type
Projects
Status
Todo