title | summary | aliases | ||
---|---|---|---|---|
Data Check for TiDB Upstream and Downstream Clusters |
Learn how to check data for TiDB upstream and downstream clusters. |
|
You can use TiDB Binlog to build upstream and downstream clusters of TiDB. When Drainer replicates data to TiDB, the checkpoint is saved and the TSO mapping relationship between the upstream and downstream is also saved as ts-map
. To check data between the upstream and downstream, configure snapshot
in sync-diff-inspector.
To obtain ts-map
, execute the following SQL statement in the downstream TiDB cluster:
mysql> select * from tidb_binlog.checkpoint;
+---------------------+---------------------------------------------------------------------------------------------------------+
| clusterID | checkPoint |
+---------------------+---------------------------------------------------------------------------------------------------------+
| 6711243465327639221 | {"commitTS":409622383615541249,"ts-map":{"primary-ts":409621863377928194,"secondary-ts":409621863377928345}} |
+---------------------+---------------------------------------------------------------------------------------------------------+
Then configure the snapshot information of the upstream and downstream databases by using the ts-map
information obtained in Step 1.
Here is a configuration example of the Databases config
section:
######################### Databases config #########################
# Configuration of the source database instance
[[source-db]]
host = "127.0.0.1"
port = 4000
user = "root"
password = "123456"
# The instance ID of the source database, the unique identifier of a database instance
instance-id = "source-1"
# Uses the snapshot function of TiDB, corresponding to the primary-ts in ts-map
snapshot = "409621863377928194"
# Configuration of the target database instance
[target-db]
host = "127.0.0.1"
port = 4001
user = "root"
password = "123456"
# Uses the snapshot function of TiDB, corresponding to the secondary-ts in ts-map
snapshot = "409621863377928345"
Note:
- Set
db-type
of Drainer totidb
to ensure thatts-map
is saved in the checkpoint.- Modify the Garbage Collection (GC) time of TiKV to ensure that the historical data corresponding to snapshot is not collected by GC during the data check. It is recommended that you modify the GC time to 1 hour and recover the setting after the check.
- In some versions of TiDB Binlog,
master-ts
andslave-ts
are stored ints-map
.master-ts
is equivalent toprimary-ts
andslave-ts
is equivalent tosecondary-ts
.