Description
F1rstLayer_Touchscreens Firmware
Calibration-PID tuning -> Bed PID -> Degrees C setting -> Keyboard is displayed shifted left, numeric input is not possible
Ender3 Pro with 4.2.7 board, CRTouch, Touchscreen firmware 7.4.9
firmware_Ender3_427_BLT_DW7.4.9.bin + F1rstLayerDwinPT_480272_20240127.7z
Clicking 70 for Bed PID displays touch keyboard shifted far to the left, only part of rightmost key column is visible. UI is responsive, it is possible to close keyboard with (X).
At the same time Nozzle PID settings (clicking 170) displays keyboard correctly.
Steps to Reproduce
- Start the printer
- On touchscreen, use item "Tools"
- On touchscreen, use item "PID Tuning"
- On touchscreen, click on Bed PID temperature setting (default 70)
Expected behavior: Touch keyboard is displayed centered, numeric input is possible.
Actual behavior: Touch keyboard is displayed shifted left, only rightmost key column is visible. It is possible to close keyboard with partially seen (x) key => it is not possible to change the setting. Nozzle PID setting displays keyboard correctly.
Additional Information
Also tested with screen rotated 180 degrees via settings, issue is the same (sans rotated).
UI use can be resumed, since (x) is partially visible. PID calibration process for both Nozzle and Bed are usable.
https://www.youtube.com/watch?v=Zq2_2FQZgLA



Description
F1rstLayer_Touchscreens Firmware
Calibration-PID tuning -> Bed PID -> Degrees C setting -> Keyboard is displayed shifted left, numeric input is not possible
Ender3 Pro with 4.2.7 board, CRTouch, Touchscreen firmware 7.4.9
firmware_Ender3_427_BLT_DW7.4.9.bin + F1rstLayerDwinPT_480272_20240127.7z
Clicking 70 for Bed PID displays touch keyboard shifted far to the left, only part of rightmost key column is visible. UI is responsive, it is possible to close keyboard with (X).
At the same time Nozzle PID settings (clicking 170) displays keyboard correctly.
Steps to Reproduce
Expected behavior: Touch keyboard is displayed centered, numeric input is possible.
Actual behavior: Touch keyboard is displayed shifted left, only rightmost key column is visible. It is possible to close keyboard with partially seen (x) key => it is not possible to change the setting. Nozzle PID setting displays keyboard correctly.
Additional Information
Also tested with screen rotated 180 degrees via settings, issue is the same (sans rotated).
UI use can be resumed, since (x) is partially visible. PID calibration process for both Nozzle and Bed are usable.
https://www.youtube.com/watch?v=Zq2_2FQZgLA