Skip to content

Latest commit

 

History

History
396 lines (270 loc) · 26.9 KB

README.md

File metadata and controls

396 lines (270 loc) · 26.9 KB

OPTIGA™: Cryptography

This example uses an OPTIGA™ Trust M V3 security solution on a PSoC™ 6 MCU to execute example code to perform available crypto operations on the secure element. This example outputs the result and the time taken to perform the crypto operations in a UART terminal.

View this README on GitHub.

Provide feedback on this code example.

Requirements

Supported toolchains (make variable 'TOOLCHAIN')

  • GNU Arm® embedded compiler v11.3.1 (GCC_ARM) - Default value of TOOLCHAIN
  • Arm® compiler v6.16 (ARM)
  • IAR C/C++ compiler v9.30.1 (IAR)

Supported kits (make variable 'TARGET')

  • Rapid IoT connect developer kit (CYSBSYSKIT-DEV-01) - Default value of TARGET
  • PSoC™ 62S2 evaluation kit (CY8CEVAL-062S2, CY8CEVAL-062S2-LAI-43439M2, CY8CEVAL-062S2-LAI-4373M2, CY8CEVAL-062S2-MUR-43439M2, CY8CEVAL-062S2-MUR-4373EM2)
  • To use this code example on different hardware, please follow this guidance

Hardware setup

This example uses the board's default configuration. See the kit user guide to ensure that the board is configured correctly.

Software setup

Install a terminal emulator if you don't have one. Instructions in this document use Tera Term.

Using the code example

Create the project and open it using one of the following:

In Eclipse IDE for ModusToolbox™ software
  1. Click the New Application link in the Quick Panel (or, use File > New > ModusToolbox™ Application). This launches the Project Creator tool.

  2. Pick a kit supported by the code example from the list shown in the Project Creator - Choose Board Support Package (BSP) dialog.

    When you select a supported kit, the example is reconfigured automatically to work with the kit. To work with a different supported kit later, use the Library Manager to choose the BSP for the supported kit. You can use the Library Manager to select or update the BSP and firmware libraries used in this application. To access the Library Manager, click the link from the Quick Panel.

    You can also just start the application creation process again and select a different kit.

    If you want to use the application for a kit not listed here, you may need to update the source files. If the kit does not have the required resources, the application may not work.

  3. In the Project Creator - Select Application dialog, choose the example by enabling the checkbox.

  4. (Optional) Change the suggested New Application Name.

  5. The Application(s) Root Path defaults to the Eclipse workspace which is usually the desired location for the application. If you want to store the application in a different location, you can change the Application(s) Root Path value. Applications that share libraries should be in the same root path.

  6. Click Create to complete the application creation process.

For more details, see the Eclipse IDE for ModusToolbox™ software user guide (locally available at {ModusToolbox™ software install directory}/docs_{version}/mt_ide_user_guide.pdf).

In command-line interface (CLI)

ModusToolbox™ software provides the Project Creator as both a GUI tool and the command line tool, "project-creator-cli". The CLI tool can be used to create applications from a CLI terminal or from within batch files or shell scripts. This tool is available in the {ModusToolbox™ software install directory}/tools_{version}/project-creator/ directory.

Use a CLI terminal to invoke the "project-creator-cli" tool. On Windows, use the command line "modus-shell" program provided in the ModusToolbox™ software installation instead of a standard Windows command-line application. This shell provides access to all ModusToolbox™ software tools. You can access it by typing modus-shell in the search box in the Windows menu. In Linux and macOS, you can use any terminal application.

The "project-creator-cli" tool has the following arguments:

Argument Description Required/optional
--board-id Defined in the <id> field of the BSP manifest Required
--app-id Defined in the <id> field of the CE manifest Required
--target-dir Specify the directory in which the application is to be created if you prefer not to use the default current working directory Optional
--user-app-name Specify the name of the application if you prefer to have a name other than the example's default name Optional

The following example clones the "mtb-example-optiga-crypto" application with the desired name "OptigaCrypto" configured for the CYSBSYSKIT-DEV-01 BSP into the specified working directory, C:/mtb_projects:

project-creator-cli --board-id CYSBSYSKIT-DEV-01 --app-id mtb-example-optiga-crypto --user-app-name OptigaCrypto --target-dir "C:/mtb_projects"

Note: The project-creator-cli tool uses the git clone and make getlibs commands to fetch the repository and import the required libraries. For details, see the "Project creator tools" section of the ModusToolbox™ software user guide (locally available at {ModusToolbox™ software install directory}/docs_{version}/mtb_user_guide.pdf).

To work with a different supported kit later, use the Library Manager to choose the BSP for the supported kit. You can invoke the Library Manager GUI tool from the terminal using make library-manager command or use the Library Manager CLI tool "library-manager-cli" to change the BSP.

The "library-manager-cli" tool has the following arguments:

Argument Description Required/optional
--add-bsp-name Name of the BSP that should be added to the application Required
--set-active-bsp Name of the BSP that should be as active BSP for the application Required
--add-bsp-version Specify the version of the BSP that should be added to the application if you do not wish to use the latest from manifest Optional
--add-bsp-location Specify the location of the BSP (local/shared) if you prefer to add the BSP in a shared path Optional

Following example adds the CY8CPROTO-062-4343W BSP to the already created application and makes it the active BSP for the app:

library-manager-cli --project "C:/mtb_projects/OptigaCrypto" --add-bsp-name CYSBSYSKIT-DEV-01 --add-bsp-version "latest-v4.X" --add-bsp-location "local"

library-manager-cli --project "C:/mtb_projects/OptigaCrypto" --set-active-bsp APP_CYSBSYSKIT-DEV-01
In third-party IDEs

Use one of the following options:

  • Use the standalone Project Creator tool:

    1. Launch Project Creator from the Windows Start menu or from {ModusToolbox™ software install directory}/tools_{version}/project-creator/project-creator.exe.

    2. In the initial Choose Board Support Package screen, select the BSP, and click Next.

    3. In the Select Application screen, select the appropriate IDE from the Target IDE drop-down menu.

    4. Click Create and follow the instructions printed in the bottom pane to import or open the exported project in the respective IDE.


  • Use command-line interface (CLI):

    1. Follow the instructions from the In command-line interface (CLI) section to create the application.

    2. Export the application to a supported IDE using the make <ide> command.

    3. Follow the instructions displayed in the terminal to create or import the application as an IDE project.

For a list of supported IDEs and more details, see the "Exporting to IDEs" section of the ModusToolbox™ software user guide (locally available at {ModusToolbox™ software install directory}/docs_{version}/mtb_user_guide.pdf).

Operation

  1. Connect the board to your PC using the provided USB cable through the KitProg3 USB connector.

  2. Open a terminal program and select the KitProg3 COM port. Set the serial port parameters to 8N1 and 115200 baud.

  3. Program the board using one of the following:

    Using Eclipse IDE for ModusToolbox™ software
    1. Select the application project in the Project Explorer.

    2. In the Quick Panel, scroll down, and click <Application Name> Program (KitProg3_MiniProg4).

    Using CLI

    From the terminal, execute the make program command to build and program the application using the default toolchain to the default target. The default toolchain is specified in the application's Makefile but you can override this value manually:

    make program TOOLCHAIN=<toolchain>
    

    Example:

    make program TOOLCHAIN=GCC_ARM
    
  4. After programming, the application starts automatically. Confirm that examples are displayed on the UART terminal.

    Figure 1. Terminal output on program startup

Debugging

You can debug the example to step through the code. In the IDE, use the <Application Name> Debug (KitProg3_MiniProg4) configuration in the Quick Panel. For details, see the "Program and debug" section in the Eclipse IDE for ModusToolbox™ software user guide.

Note: (Only while debugging) On the CM4 CPU, some code in main() may execute before the debugger halts at the beginning of main(). This means that some code executes twice – once before the debugger stops execution, and again after the debugger resets the program counter to the beginning of main(). See KBA231071 to learn about this and for the workaround.

Design and implementation

This example initializes the OPTIGA™ Trust device by calling a dedicated function from the platform abstraction layer (PAL). This function initializes all hardware and system-relevant components. Afterward, the example sequentially calls isolated sub-examples to showcase various API combinations.

All examples follow the same pattern init function, do_crypto function, and an optional deinit function. The following snippets provide an overview:

void example_main(void)
{
   uint8_t random_data_buffer [32];
   optiga_crypt_t * me_crypt_instance = NULL;
   optiga_lib_status_t return_status = !OPTIGA_LIB_SUCCESS;

   do
   {
      /*
      * Step 1. Initialize the OPTIGA device
      */
      example_optiga_init();

      /*
      * Step 2. Create an instance of optiga_crypt to perform any crypto operation on the OPTIGA device.
      */
      me_crypt_instance = optiga_crypt_create(0, optiga_lib_callback, NULL);
      if (NULL == me_crypt_instance)
      {
            break;
      }

      /*
      * Step 3..n-1. Perform any operation with the OPTIGA device; e.g., get a true random number.
      * random_data_buffer should contain the resulting random number.
      */
      optiga_lib_status = OPTIGA_LIB_BUSY;
      return_status = optiga_crypt_random(me_crypt_instance,
                                          OPTIGA_RNG_TYPE_TRNG,
                                          random_data_buffer,
                                          sizeof(random_data_buffer));

      WAIT_AND_CHECK_STATUS(return_status, optiga_lib_status);

      /* Step n. De-initialize the OPTIGA device. This step is optional in many cases because some resources on MCU-based systems cannot be de-initialized.
      */
      example_optiga_deinit();
   } while (FALSE);
}

OPTIGA™ init and deinit functions simply allocate a new command context and send an OpenApplication command to the chip. The while loop is required to synchronize the state machine. The application is free to implement this differently and check the status occasionally; the rest might be in an idle state.

#include "optiga/optiga_crypt.h"
#include "optiga/optiga_util.h"
#include "optiga/optiga_lib_config.h"


optiga_util_t * me_util_instance = NULL;
optiga_crypt_t * me_crypt_instance = NULL;

/**
 * Callback when optiga_util_xxxx operation is completed asynchronously
 */
static volatile optiga_lib_status_t optiga_lib_status;
//lint --e{818} suppress "argument "context" is not used in the sample provided"
static void optiga_lib_callback(void * context, optiga_lib_status_t return_status)
{
   optiga_lib_status = return_status;
   if (NULL != context)
   {
      // callback to upper layer here
   }
}

// Check return status
#define WAIT_AND_CHECK_STATUS(return_status, optiga_lib_status)\
                            if (OPTIGA_LIB_SUCCESS != return_status)\
                            {\
                                break;\
                            }\
                            while (OPTIGA_LIB_BUSY == optiga_lib_status)\
                            { }\
                            if (OPTIGA_LIB_SUCCESS != optiga_lib_status)\
                            {\
                                return_status = optiga_lib_status;\
                                break;\
                            }

void example_optiga_init(void)
{
    optiga_lib_status_t return_status = !OPTIGA_LIB_SUCCESS;

    do
    {
        if (NULL == me_util_instance)
        {
           /*
           Create an instance of optiga_util to open the application on the OPTIGA device.
           */
           me_util_instance = optiga_util_create(0, optiga_lib_callback, NULL);
           if (NULL == me_util_instance)
           {
               break;
           }
        }

        /**
         * Open the application on the OPTIGA device which is a precondition to perform any other operations
         * using the optiga_util_open_application.
         */
        optiga_lib_status = OPTIGA_LIB_BUSY;
        return_status = optiga_util_open_application(me_util_instance, 0);

        WAIT_AND_CHECK_STATUS(return_status, optiga_lib_status);

    }while(FALSE);
}

void example_optiga_deinit(void)
{
    optiga_lib_status_t return_status = !OPTIGA_LIB_SUCCESS;

    do
    {
        /**
         * Close the application on the OPTIGA device after all the operations are executed
         * using optiga_util_close_application.
         */
        optiga_lib_status = OPTIGA_LIB_BUSY;
        return_status = optiga_util_close_application(me_util_instance, 0);

        WAIT_AND_CHECK_STATUS(return_status, optiga_lib_status);

        // Destroy util and crypt instances
        optiga_util_destroy(me_util_instance);
        me_util_instance = NULL;
    }while(FALSE);
}

Resources and settings

Several settings can be controlled:

OPTIGA™ Trust M pins Assigned GPIOs by default Notes
I2C SDA (I/O) CYBSP_TRUSTM_I2C_SDA Any GPIO connected to the I2C SDA line can be used.
I2C SCL (Clock) CYBSP_TRUSTM_I2C_SCL Any GPIO connected to the I2C SDA line can be used.
RST (Reset) CYBSP_TRUSTM_RST An optional control pin if defined in optiga_lib_config_mtb.h
VDD (Power control) (Optional) CYBSP_TRUSTM_VDD An optional control pin if defined in optiga_lib_config_mtb.h

optiga_lib_config_mtb.h macros Meaning Default value
OPTIGA_CRYPT_XXXX Controls whether to enable/disable selected crypto support on the host library side All are enabled
OPTIGA_COMMS_SHIELDED_CONNECTION and OPTIGA_COMMS_DEFAULT_PROTECTION_LEVEL Together define whether to use and the extent of use of the shielded connection (encrypted and integrity-protected I2C communication) Defined OPTIGA_COMMS_SHIELDED_CONNECTION
OPTIGA_COMMS_DEFAULT_RESET_TYPE The reset type if VDD or RST pins are defined. Choose 1 or 2 depending on the combination used. VDD can be used in certain cases as a reset line, but it is recommended to use them separately. 2
OPTIGA_CMD_MAX_REGISTRATIONS Controls the number of crypt/util registrations allowed. In a very basic scenario, this can be reduced to 2 (one registration each for crypt and util) 6
OPTIGA_MAX_COMMS_BUFFER_SIZE Maximum buffer size that the command layer should be able to store intermediately 0x615
OPTIGA_LIB_ENABLE_LOGGING Controls whether logging can be enabled in general Defined
OPTIGA_LIB_ENABLE_UTIL_LOGGING If defined together with OPTIGA_LIB_ENABLE_LOGGING, outputs util API-relevant messages Undefined
OPTIGA_LIB_ENABLE_CRYPT_LOGGING If defined together with OPTIGA_LIB_ENABLE_LOGGING, outputs crypt API-relevant messages Undefined
OPTIGA_LIB_ENABLE_CMD_LOGGING If defined together with OPTIGA_LIB_ENABLE_LOGGING, outputs APDU sent to the OPTIGA™ Trust M external interface (See the solution reference manual) Undefined
OPTIGA_LIB_ENABLE_COMMS_LOGGING If defined together with OPTIGA_LIB_ENABLE_LOGGING, prints out I2C frames Undefined

Related resources

Resources Links
Application notes AN228571 – Getting started with PSoC™ 6 MCU on ModusToolbox™ software
AN221774 – Getting started with PSoC™ 6 MCU on PSoC™ Creator
AN210781 – Getting started with PSoC™ 6 MCU with Bluetooth® Low Energy connectivity on PSoC™ Creator
AN215656 – PSoC 6 MCU: Dual-CPU system design
Code examples on GitHub Using ModusToolbox™ software
Device documentation PSoC™ 6 MCU datasheets
PSoC™ 6 technical reference manuals
OPTIGA™ Trust M datasheet
Development kits Select your kits from the evaluation board finder
Libraries on GitHub mtb-pdl-cat1 – PSoC™ 6 peripheral driver library (PDL)
mtb-hal-cat1 – Hardware abstraction layer (HAL) library
retarget-io – Utility library to retarget STDIO messages to a UART port
Middleware on GitHub optiga-trust-m – OPTIGA™ Trust M library and documents
psoc6-middleware – Links to all PSoC™ 6 MCU middleware
Tools Eclipse IDE for ModusToolbox™ software – ModusToolbox™ software is a collection of easy-to-use software and tools enabling rapid development with Infineon MCUs, covering applications from embedded sense and control to wireless and cloud-connected systems using AIROC™ Wi-Fi and Bluetooth® connectivity devices.

Other resources

Infineon provides a wealth of data at www.infineon.com to help you select the right device, and quickly and effectively integrate it into your design.

For PSoC™ 6 MCU devices, see How to design with PSoC™ 6 MCU - KBA223067 in the Infineon community.

Document history

Document title: CE233693OPTIGA™: Cryptography

Version Description of change
1.0.0 New code example
2.0.0 Updated to support ModusToolbox™ software v3.0 and BSPs v4.X
2.1.0 Added support for new kits


© Cypress Semiconductor Corporation, 2021-2023. This document is the property of Cypress Semiconductor Corporation, an Infineon Technologies company, and its affiliates ("Cypress"). This document, including any software or firmware included or referenced in this document ("Software"), is owned by Cypress under the intellectual property laws and treaties of the United States and other countries worldwide. Cypress reserves all rights under such laws and treaties and does not, except as specifically stated in this paragraph, grant any license under its patents, copyrights, trademarks, or other intellectual property rights. If the Software is not accompanied by a license agreement and you do not otherwise have a written agreement with Cypress governing the use of the Software, then Cypress hereby grants you a personal, non-exclusive, nontransferable license (without the right to sublicense) (1) under its copyright rights in the Software (a) for Software provided in source code form, to modify and reproduce the Software solely for use with Cypress hardware products, only internally within your organization, and (b) to distribute the Software in binary code form externally to end users (either directly or indirectly through resellers and distributors), solely for use on Cypress hardware product units, and (2) under those claims of Cypress’s patents that are infringed by the Software (as provided by Cypress, unmodified) to make, use, distribute, and import the Software solely for use with Cypress hardware products. Any other use, reproduction, modification, translation, or compilation of the Software is prohibited.
TO THE EXTENT PERMITTED BY APPLICABLE LAW, CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS DOCUMENT OR ANY SOFTWARE OR ACCOMPANYING HARDWARE, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. No computing device can be absolutely secure. Therefore, despite security measures implemented in Cypress hardware or software products, Cypress shall have no liability arising out of any security breach, such as unauthorized access to or use of a Cypress product. CYPRESS DOES NOT REPRESENT, WARRANT, OR GUARANTEE THAT CYPRESS PRODUCTS, OR SYSTEMS CREATED USING CYPRESS PRODUCTS, WILL BE FREE FROM CORRUPTION, ATTACK, VIRUSES, INTERFERENCE, HACKING, DATA LOSS OR THEFT, OR OTHER SECURITY INTRUSION (collectively, "Security Breach"). Cypress disclaims any liability relating to any Security Breach, and you shall and hereby do release Cypress from any claim, damage, or other liability arising from any Security Breach. In addition, the products described in these materials may contain design defects or errors known as errata which may cause the product to deviate from published specifications. To the extent permitted by applicable law, Cypress reserves the right to make changes to this document without further notice. Cypress does not assume any liability arising out of the application or use of any product or circuit described in this document. Any information provided in this document, including any sample design information or programming code, is provided only for reference purposes. It is the responsibility of the user of this document to properly design, program, and test the functionality and safety of any application made of this information and any resulting product. "High-Risk Device" means any device or system whose failure could cause personal injury, death, or property damage. Examples of High-Risk Devices are weapons, nuclear installations, surgical implants, and other medical devices. "Critical Component" means any component of a High-Risk Device whose failure to perform can be reasonably expected to cause, directly or indirectly, the failure of the High-Risk Device, or to affect its safety or effectiveness. Cypress is not liable, in whole or in part, and you shall and hereby do release Cypress from any claim, damage, or other liability arising from any use of a Cypress product as a Critical Component in a High-Risk Device. You shall indemnify and hold Cypress, including its affiliates, and its directors, officers, employees, agents, distributors, and assigns harmless from and against all claims, costs, damages, and expenses, arising out of any claim, including claims for product liability, personal injury or death, or property damage arising from any use of a Cypress product as a Critical Component in a High-Risk Device. Cypress products are not intended or authorized for use as a Critical Component in any High-Risk Device except to the limited extent that (i) Cypress’s published data sheet for the product explicitly states Cypress has qualified the product for use in a specific High-Risk Device, or (ii) Cypress has given you advance written authorization to use the product as a Critical Component in the specific High-Risk Device and you have signed a separate indemnification agreement.
Cypress, the Cypress logo, and combinations thereof, WICED, ModusToolbox, PSoC, CapSense, EZ-USB, F-RAM, and Traveo are trademarks or registered trademarks of Cypress or a subsidiary of Cypress in the United States or in other countries. For a more complete list of Cypress trademarks, visit www.infineon.com. Other names and brands may be claimed as property of their respective owners.