Investigation on single_step_call #140
Comments
Are you saying that |
After digging into the rabbit hole, it appears that we were misunderstanding the description of call get_param(param_file, mdl, "SINGLE_STEPPING_CALL", OS%single_step_call, &
"If true, advance the state of MOM with a single step "//&
"including both dynamics and thermodynamics. If false, "//&
"the two phases are advanced with separate calls.", default=.true.)
But both dynamics and thermodynamics advance together within a single subroutine call. Hence, Conversely, when |
I am now investigating why diagnostics are not exactly the same when turning it on and off. |
This is still confusing to me. If dynamics and thermo are advanced in a single call with |
Hi @aekiss After that, call step_MOM_dynamics(forces, CS%p_surf_begin, CS%p_surf_end, dt, &
dt_therm_here, bbl_time_int, CS, &
Time_local, Waves=Waves) |
Ah, ok thanks for the clarification. So
In both cases it looks (on a superficial skim) like within each coupling timestep the model loops over |
Yes, I think you are right. From my understading, when |
Description
As was proposed in ACCESS-NRI/access-om3-configs#48 (comment), there seems to be a discrepancy regarding the behavior of the
single_step_call
as described in the documentation and its actual implementation.According to the documentation snippet provided here,
single_step_call
parameter is in defaultTrue
, hence MOM advances its state with a single timestep, whereDT_THERMO
is neglected.Issue
However, this is not the case. That is, when
SINGLE_STEPPING_CALL
=True&
THERMO_SPANS_COUPLING
=True, MOM does not advance with a single timestep!Finding
dt_therm
is still in effect even whensingle_step_call
is set to True. This observation is further confirmed by a sanity check via print outputs.single_step_call
, the time consumption remains the same between two runs withthermo_does_span_coupling=True, dt=1350, and dt_thermo=2700
. Both are around 25% faster than a comparison run withthermo_does_span_coupling=False
I am currently investigating this issue as there seems to be some aspect that I am not yet aware of. This issue is considered critical as it could potentially affect the integrity of model solutions if left unresolved.