fix typo switchmode 14
value 13 was used in descrtiption of switchmode 14
1 parent 5a8dcd6 commit 83f1c8f

File tree

1 file changed

+1
-1
lines changed

1 file changed

+1
-1
lines changed

docs/Commands.md

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -134,7 +134,7 @@ Power<x\><a class="cmnd" id="power"></a>|Control the corresponding power state (
134134
PowerOnState<a class="cmnd" id="poweronstate"></a>|Control power state when the device is _**powered up**_. [More information](PowerOnState)<BR> `0` / `OFF` = keep power(s) OFF after power up <BR> `1` / `ON` = turn power(s) ON after power up <BR> `2` / `TOGGLE` = toggle power(s) from last saved state <BR> `3` = switch power(s) to their last saved state *(default)* <BR> `4` = turn power(s) ON and disable further power control <BR> `5` = after a `PulseTime` period turn power(s) ON (acts as inverted [`PulseTime`](Commands.md#pulsetime) mode)
135135
PulseTime<x\><a class="cmnd" id="pulsetime"></a>|Display the amount of `PulseTime` remaining on the corresponding Relay<x\><BR>`<value>` Set the duration to keep Relay<x\> `ON` when `Power<x> ON` command is issued. After this amount of time, the power will be turned `OFF`.<BR>`0` / `OFF` = disable use of PulseTime for Relay<x\><BR>`1..111` = set PulseTime for Relay<x\> in 0.1 second increments<BR>`112..64900` = set PulseTime for Relay<x\>, offset by 100, in 1 second increments. Add 100 to desired interval in seconds, e.g., `PulseTime 113` = 13 seconds and `PulseTime 460` = 6 minutes (i.e., 360 seconds)<BR>
136136
SwitchDebounce<a class="cmnd" id="switchdebounce"></a>|User control over switch debounce timing and method<BR>`40..1000` = set switch debounce time in milliseconds *(default = `50`)*. The granularity is 10 milliseconds, so the normally unnecessary last digit is used by the debouncing code to flag special handling: <BR> `0` = no special handling <BR> `1` = force_high: only a debounce time long LOW pulse could turn the switch off <BR> `2` = force_low: only a debounce time long HIGH pulse could turn the switch on <BR> `3` = force_high + force_low <BR> `4..8` = unused <BR> `9` = AC detection for switches / relays similar to MOES MS-104B / BlitzWolf SS5 etc. If the AC frequency is 50 Hz, `SwitchDebounce 69` will turn on the switch after three pulses and off after three missing one.
137-
SwitchMode<x\><a class="cmnd" id="switchmode"></a>|[Switch mode](Buttons-and-Switches#switchmode) <BR> `0` = toggle *(default)* <BR> `1` = follow (0 = off, 1 = on) <BR> `2` = inverted follow (0 = on, 1 = off) <BR> `3` = pushbutton (default 1, 0 = toggle) <BR> `4` = inverted pushbutton (default 0, 1 = toggle) <BR> `5` = pushbutton with hold (default 1, 0 = toggle, Hold = hold) <BR> `6` = inverted pushbutton with hold (default 0, 1 = toggle, hold = hold) <BR> `7` = pushbutton toggle (0 = toggle, 1 = toggle)<BR> `8` = multi change toggle (0 = toggle, 1 = toggle, 2x change = hold)<BR> `9` = multi change follow (0 = off, 1 = on, 2x change = hold)<BR> `10` = inverted multi change follow (0 = on, 1 = off, 2x change = hold)<BR> `11` = pushbutton with dimmer mode <BR> `12` = inverted pushbutton with dimmer mode <BR> `13` = pushon mode (1 = on, switch off using `PulseTime`)<BR> `13` = inverted pushon mode (0 = on, switch off using `PulseTime`)
137+
SwitchMode<x\><a class="cmnd" id="switchmode"></a>|[Switch mode](Buttons-and-Switches#switchmode) <BR> `0` = toggle *(default)* <BR> `1` = follow (0 = off, 1 = on) <BR> `2` = inverted follow (0 = on, 1 = off) <BR> `3` = pushbutton (default 1, 0 = toggle) <BR> `4` = inverted pushbutton (default 0, 1 = toggle) <BR> `5` = pushbutton with hold (default 1, 0 = toggle, Hold = hold) <BR> `6` = inverted pushbutton with hold (default 0, 1 = toggle, hold = hold) <BR> `7` = pushbutton toggle (0 = toggle, 1 = toggle)<BR> `8` = multi change toggle (0 = toggle, 1 = toggle, 2x change = hold)<BR> `9` = multi change follow (0 = off, 1 = on, 2x change = hold)<BR> `10` = inverted multi change follow (0 = on, 1 = off, 2x change = hold)<BR> `11` = pushbutton with dimmer mode <BR> `12` = inverted pushbutton with dimmer mode <BR> `13` = pushon mode (1 = on, switch off using `PulseTime`)<BR> `14` = inverted pushon mode (0 = on, switch off using `PulseTime`)
138138
SwitchText<x\><a class="cmnd" id="switchtext"></a>|Show current JSON label of `Switch<x>` (`1..8`). Only `SwitchText` shows value for all 8 switches<BR>`<text>` - replace default `Switch<x>` label in JSON messages with a custom text<BR>
139139
Webbutton<x\><a class="cmnd" id="webbutton"></a>|Change the name of the toggle buttons of the WEB UI. This command accepts spaces in the name
140140
See also|[`SetOption1`](#setoption1) - Set button multipress mode<BR>[`SetOption11`](#setoption11) - Swap pushbutton single and double press functionality<BR>[`SetOption13`](#setoption13) - Allow immediate action on single button press<BR>[`SetOption26`](#setoption26) - Use indexes even when only one relay is present<BR>[`SetOption31`](#setoption31) - Disable Wi-Fi LED status blinking<BR>[`SetOption32`](#setoption32) - Set hold interval before sending `HOLD` action<BR>[`SetOption40`](#setoption40) - Stop detecting any input change on button GPIO<BR>[`SetOption67`](#setoption67) - Enable/Disable Buzzer<BR>[`SetOption73`](#setoption73) - Decouple buttons from controlling power outputs